  • Page 1 MODEL SPECIFIC OPERATIONAL MANUAL architect series...
  • Page 2: Table Of Contents

    table of contents 1. Introduction 2. General information 2.1 What is a laser and how does it work? 2.2 Laser Safety first! 2.3 Installation ofthe System 2.4 Control System 2.5 Control Options 2.6 Connection Diagram 2.7 Multiple System Interlock 2.8 Switching ON sequence and User Interlock 2.9 Maintenance 3.
  • Page 3: Introduction

    Thank you for purchasing this KVANT product. To ensure proper operation, please read this manual carefully before using the product. After reading it, keep it in a safe place for future reference.
  • Page 4: General Information

    LASER LIGHT IS BRIGHT AND BLINDING DO NOT SHINE AT IEC 60825 - 1:2014 AIRCRAFT OR VEHICLES AT ANY DISTANCE KVANT This product is in conformity with performance CAUTION standards for laser products under 21 CFR Part 1010.4 and 1040.11 except with respect...
  • Page 5 The manufacturer and its distributors cannot be  held responsible for any damages caused by  improper use or  misuse of  this KVANT laser system. Please note that some other optical devices such The owner/user is  fully responsible for as  cameras, camcorders, video projector etc. can using this product in accordance to laser...
  • Page 6: What Is A Laser And How Does It Work

    what is a laser and how does it work? What is a LASER? The laser is a device that creates continuous visible light energy waves (streams of photons that are referred to as “laser radiation”) with the same amplitude and phase that are flowing in the same direction; meaning they are coherent – they stick together and form a laser beam.
  • Page 7: Laser Safety First

    laser safety first! Any laser system classified as a Class Before proceeding any further, please 4 laser must be  used with caution. read the following safety page very If  you are an  inexperienced laser carefully. It  could help you avoid operator, we  strongly recommend dangerous and hazardous situations that you attend a ...
  • Page 8: Installation Ofthe System

    installation of the system Please follow these rules during the installation: The manufacturer is not liable for damages or  a  injury caused by  improper installation of  the system. The installation should Do not connect the device to power supply during be  carried by  a  qualified installer who the installation.
  • Page 9: Control System

    Please make sure all the laser settings in  your control dependent on the control system that you use for operating system are set correctly before you start using your Kvant the laser as well as the correct device configuration in the laser display system.
  • Page 10: Control Options

    Analog control option E-STOP remote and Remote Controller view Kvant Architect laser system with analog control option is dedicated to display static beams with locally adjustable brightness for each of R, G or B colour. Remote controller with adjusters for each colour is supplied with each fixture.
  • Page 11: Connection Diagram

    connection diagram Please check that all the control and power leads and interlock door circuitry are correctly connected. Please see i  E-STOP Remote safety must following connection diagram. be inserted and switched to ON position in order to disable the interlock. i  Shutter key must be inserted and switched to ...
  • Page 12: Multiple System Interlock

    E-STOP Remote to each plugged Architect laser system and they are fully compatible with all Kvant laser systems using E-STOP Remote standard. The E-STOP splitter has two inputs, thus two E-STOP Remotes can be used and you can control the Architect laser systems...
  • Page 13: Switching On Sequence And User Interlock

    3. Safety key Switch on  E-STOP Remote turned to  OFF position. 4. Shutter key turned to OFF position 5. E-STOP Remote disconnected from KVANT Architect laser system. 6. Door interlock circuitry connected to  the E-STOP Remote interlock connector is  open. Door interlock may be ...
  • Page 14 E-Stop IN Connector "User E-Stop Connector" on "Kvant E-Stop Box". (XLR Female) If "User E-Stop switch" is connected to "Kvant E-Stop Box" and is in OPEN state, all "Kvant Laser projetors" connected to "Kvant E-Stop Box" are disabled. In this case NO EMISSION is possible.
  • Page 15: Maintenance

    Outdoor installation inside the cartridges. That can be done and also interior operation of KVANT laser system requires through the opening in the middle of the cartridge. If  the colour of the granules special care of ...
  • Page 16: Item Checklist

    Before starting, check that all the following items have been included with your laser system. If anything is missing, contact your supplier. Item Number of units Descriptions KVANT Architect Laser System 1x  Emergency STOP remote and Remote Controller US version BUS ID: 1647...
  • Page 17: System Overview

    KVANT Architect is  a  full colour, semiconductor diode The system is  fluid cooled and designed with no  airflow laser system designed for professional laser illumination going through the optical compartment of  the system. purposes and static visual beam effects.
  • Page 18: Top View

    top view 1. Laser apertures. 2. Laser emission indicator. 3. 10pcs top cover fast access When this indicator is  lit up  the laser fasteners. system can emit the laser radiation. To  access the optical compartment of  the laser system pull up  the fasteners and release the clamps from hooks and carefully remove the top cover.
  • Page 19: Side View

    2. E-STOP Remote input cable. 3. Input signal cable. In  order to  use the laser system, the Kvant Architect systems use either Interlock must be  closed circuit. This analog input levels 0-5V or  DMX is  done by  connecting the E-STOP siglnal to ...
  • Page 20: Beam Alignment

    beam alignment It  is  possible that due to  transportation, rigging, moving around or  vibrations caused by  various elements during This Architect laser system is  rated as  a  Class IV laser product and a set up or laser performance some of the internal optical manufactured in ...
  • Page 21: Architect Beam Alignment

    4. Set small brightness of one of three colour channels Although KVANT uses the latest you want to align (either R, G or B) on your DMX technology to protect all the critical or remote controller. Keep other two colour channels components inside this laser system at zero level (other two colours have no output).
  • Page 22: Technical Specifications

    technical specifications All the technical specifications are subject to change without prior notice.
  • Page 23: Technical Specifications [Architect A270B - White Balanced]

    technical specifications [architect a b - white balanced] Low divergent, high power, full colour, full diode, static architectural laser source Total optical power 270W consist of: 112W red, 96W green, 64W blue Total luminous flux: 63 700 lm Air cooled version. General specifications Green Blue...
  • Page 24: Technical Specifications [Architect W270B - White Balanced]

    technical specifications [architect w b - white balanced] Low divergent, high power, full color, full diode, static architectural laser source Total optical power 270W consisting of: 112W red, 96W green, 64W blue Total luminous flux: 63 700 lm Water cooled version General specifications Green Blue...
  • Page 25: Technical Specifications [Architect A300]

    technical specifications [architect a Low divergent, high power, full color, full diode, static architectural laser source Total optical power 300W consist of: 45W red, 192W green, 64W blue Total luminous flux: 101 000 lm Air cooled version General specifications Green Blue White Optical power (at the laser head output)
  • Page 26: Technical Specifications [Architect W300]

    technical specifications [architect w Low divergent, high power, full color, full diode, static architectural laser source Total optical power 300W consist of: 45W red, 192W green, 64W blue Total luminous flux: 101 000 lm Water cooled version General specifications Green Blue White Optical power (at the laser head output)
  • Page 27: Technical Specifications [Architect W660B - White Balanced]

    technical specifications [architect w b - white balanced] Low divergent, high power, full color, full diode, static architectural laser source Total optical power 600W consist of: 269W red, 224W green, 168W blue Total luminous flux: 150 000 lm Water cooled version General specifications Green Blue...
  • Page 28: Technical Specifications [Architect W960B - White Balanced]

    technical specifications [architect w b - white balanced] Low divergent, high power, full color, full diode, static architectural laser source Total optical power 900W consist of: 365W red, 305W green, 230W blue Total luminous flux: 203 600 lm Water cooled version General specifications Green Blue...