Delta 59-PLGHDF Series Installation Instructions Manual
Delta 59-PLGHDF Series Installation Instructions Manual

Delta 59-PLGHDF Series Installation Instructions Manual

Advertisement

Quick Links

HDF Spout Assembly
061203A
Vandal Resistant Laminar Outlet
with Wrench
0.5 GPM (1.9 L/min)
060638A - Optional
Vandal Resistant Laminar Outlet
with Antimicrobial by Agion
1.5 GPM (5.7 L/min)
060640A - Optional
Vandal Resistant Flow Control
Aerator and Wrench
1.5 GPM (5.7 L/min)
060642A - Optional
Flow Control Aerator
1.5 GPM (5.7 L/min)
RP31704 - Optional
Vandal Resistant Spray Outlet
with Wrench
0.5 GPM (1.9 L/min)
060566A - Optional
Vandal Resistant Spray Outlet
with Wrench
1.0 GPM (3.8 L/min)
NOTE: For optimum performance of this product, we
recommend a system pressure between 20 and 80 PSI
static. This product will operate up to a maximum of
125 PSI static per ANSI and CSA requirements. However,
we do not recommend pressure above 80 PSI. Thermal
expansion or leaking pressure reducing valves may
require use of expansion tanks or relief valves to ensure
your system never exceeds its maximum intended
pressure setting.
060905A
Cover Gasket
060906A
Surface
Mount Housing
061252A
Dual
Driver Board
063128A
Battery Box Assembly less driver
board and battery holder
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
063129A
for Proximity
®
060765A
Wrench
063127A
Solenoid Valve with 3/8"
Compression Connectors
060908A
Solenoid Holder
060909A
Screen Assembly
063131A
3/8" Comp Connect Nut
and Ferrile
062032A
Braided
Polymer Hose
__
59
-PLGHDF
Write purchase model number here for future reference
RP30522
Gasket
060683A
24VAC to 6VDC Converter
061259A
Ground Wire Kit (for hardwire models)
061047A
24VAC to 6VDC Converter with
Battery Backup
w w w . s p e c s e l e c t . c o m
Page 1
__ __
061159A
4" Deck Plate
& Holddown Pkg
061160A
8" Deck Plate
& Holddown Pkg
RP6092
Nut & Washer
061175A
Spacer package for
HDF Proximity
RP6087
Nut &
Washer
061206A
Proximity
Sensor
Module
OPTION LIST
061255A
Battery Holder - Square (4 "AA")
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
060772A
Transformer 110 to 24 VAC 100VA
up to 25 Electronic Valves
DECK PLATES
061159A
4" Deck Plate & Holddown Pkg.
061160A
8" Deck Plate & Holddown Pkg.
208623 Rev. B

Advertisement

Table of Contents
loading

Summary of Contents for Delta 59-PLGHDF Series

  • Page 1 __ __ -PLGHDF Write purchase model number here for future reference 061159A 063129A 4” Deck Plate HDF Spout Assembly & Holddown Pkg for Proximity 061160A 8” Deck Plate & Holddown Pkg 061203A Vandal Resistant Laminar Outlet with Wrench 0.5 GPM (1.9 L/min) 060638A - Optional RP6092 Vandal Resistant Laminar Outlet...
  • Page 2: Installation And Set Up Instructions

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. INSTALLATION AND SET UP INSTRUCTIONS FOR SURFACE MOUNT HOUSING: CONTROL BOX #0 Fig. 1 STEP 1. FAUCET INSTALLATION Spout Mount faucet to sink using the provided components in the following order - grey bottom spacer, washer, lock nut (Fig.
  • Page 3 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. INSTALLATION AND SET UP INSTRUCTIONS FOR SURFACE MOUNT HOUSING: CONTROL BOX #0 Fig. 5 STEP 7a. CONNECT POWER (Cont’d) HARDWIRE CALIBRATION (Cont’d) : Turn on power supply for the transformer.
  • Page 4: Making Adjustments

    MAKING ADJUSTMENTS FOR CONTROL BOX #0 The factory defaults for all settings are shown in the Quick Reference Chart below. If these are acceptable, the driver board is ready for use. If changes are required, follow the instructions to make adjustments. DRIVER BOARD QUICK REFERENCE CHART Factory Symbol...
  • Page 5 - Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on) If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical Services at 1-800-387-8277.
  • Page 6: Care Instructions

    CARE INSTRUCTIONS This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards. With proper care, it will give years of trouble free service. Care should be given to the cleaning of this product. Although the chrome finish is extremely durable, it can be DAMAGED by ACIDIC CLEANERS (i.e.
  • Page 7 TROUBLESHOOTING GUIDE Check to ensure faucet was installed Note: See attached M&I, pages 1 to 5. according to the M&I sheet. Verify spacers are in place; black spacer on top and grey spacer on the Test for operation. If unit does not bottom of the sink or counter.
  • Page 8 Delta Commercial Faucet Limited Warranty All parts of the Delta® HDF® and TECK® faucets are warranted to the original consumer purchaser to be free from defects in material, finish and workmanship for a period of five (5) years unless otherwise specifically stated in the catalogue and price book. This warranty is made to the original consumer purchaser and shall be effective from date of purchase as shown on purchaser’s receipt.

This manual is also suitable for:

590-plghdf series