Making Adjustments - Delta 59-PLGHDF Series Installation Instructions Manual

Table of Contents

Advertisement

FOR CONTROL BOX #0
The factory defaults for all settings are shown in the Quick Reference Chart below. If these are acceptable, the driver board is ready
for use. If changes are required, follow the instructions to make adjustments.
Symbol
Function
d
Sensor
Sensitivity
Auto Timer
T
(faucet shut-off)
R
Rinse Cycle
r
Rinse Time
b
Buzzer
M
Metering Mode

MAKING ADJUSTMENTS

DRIVER BOARD QUICK REFERENCE CHART
Description
This setting adjusts how sensitive the faucet will be on a 10 point
scale. These are relative sensitivities and do not directly
correspond to a measured distance.
This timeout will shut off flow in the event the sensor continually
sees a target. It is not used if metering mode is set.
If this feature is turned to an "xx" hour value, the faucet will turn
on itself after this set time from last use.
This is the amount of time you want the faucet to stay on to move
the water in the line, if the Rinse Cycle is made active.
Buzzer will annunciate during power up, calibration or to indicate
low power.
This feature changes the product into a metering faucet; it will run
the full set amount of time after the user's hands are first detected.
If this feature is enabled, the timeout setting will be ignored.
w w w . s p e c s e l e c t . c o m
Page 4
Factory
Function Settings
Default Setting
1 to 10
Sensitivity setting
5
5, 7, 10, 12, 15, 30, 45, 60, 75, 90
45 seconds
seconds
2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0,
9.9 minutes
- (OFF), 6, 12, 18, 24, 30, 36,
--
42, 48 hours
10 seconds
10, 20, 30, 40, 50, 60, 90 seconds
(once enabled)
2.0, 2.5, 3.0 minutes
ON, - (OFF)
ON
-- (OFF), 7, 8, 9, 10, 11, 12, 13,
--
14, 15, 18, 24, 30, 40, 50, 60, 90
seconds
2.0, 2.5, 3.0, 3.5, 4.0 minutes