Allen-Bradley B Series Quick Reference
Allen-Bradley B Series Quick Reference

Allen-Bradley B Series Quick Reference

Integrated drive/motor
Hide thumbs Also See for B Series:

Advertisement

Quick Links

Fault Codes
Fault Code
Fault Description
Communication Loss
Keyboard Disconnected
Parameter Checksum
Keypad connected while under power
DeviceNet Communication Fault
X
( X = E, F, L, P, or U)
Keypad connected while under power
Keypad Redundant Start
Function Loss
Overvoltage
EEPROM Drive ID
Undervoltage
Overcurrent
Overtemperature
Overload
TB Redundant Start
Internal Fault
( NNN = a number between 0 and 999)
Setting the Operating Speed Before
Starting the Unit
Standard units: Use the speed potentiometer or
other user-supplied external speed reference
device.
Units with local operator controls: As shipped
from the factory, the unit receives its speed
reference from the keypad. Use the
increase the speed reference and the
to decrease the speed reference.
To use the analog input terminals for the speed
reference, setup switch 2 (Speed Reference
Select) must be in the ON position. In this case,
the
keys are not used.
At subsequent power ups, the unit will use the
last speed reference setting selected before
power was removed.
Using the Local Operator Controls
Desired Action
Start the unit.
Stop the unit.
Change motor
rotation direction.
Clear faults or abort
Auto Restart
sequence.
Decrease the speed
reference.
Display the current
speed or load.
Display the speed in
RPM.
Display %load.
Increase the speed
reference.
key to
key
User Steps
Press the green
key.
Press the red
key.
Press the
key.
RESET
Press the
key.
Press the
key until the
speed reference displayed
is the desired value. The
longer the
key is held
down, the faster the value
will change.
Press the
or
key once.
The display will return to indicating
speed in RPM or %load after three to
five seconds.
No action required; speed in RPM is
the default display based on terminal
12.
Close switch on terminal 12.
Press the
key until the
speed reference displayed is the
desired value. The longer the
key is held down, the faster the value
will change.
1329I
Integrated Drive/Motor
(Series B)
Quick Reference
IMPORTANT: This publication is designed as a reference
tool. The Bulletin 1329I User Manual and 1329I DeviceNet
Option User Manual must be consulted for more detailed
information about operation and hazards of personal
injury.
Publication 1329I-5.6 – January, 2000
P/N 194445 (01)

Advertisement

loading

Summary of Contents for Allen-Bradley B Series

  • Page 1 Fault Codes To use the analog input terminals for the speed reference, setup switch 2 (Speed Reference Fault Code Fault Description Select) must be in the ON position. In this case, keys are not used. Communication Loss At subsequent power ups, the unit will use the Keyboard Disconnected 1329I last speed reference setting selected before...
  • Page 2 Max Speed Switch (SW2) Accel/Decel Switch (SW1) ATTENTION: All adjustments to these components should be made with the power removed. Failure to 0 = 1 Second Accel/5 Sec Decel 0 = 1500 RPM (50 Hz) observe this precaution could result in severe bodily 1 = 5 Seconds (Default) 1 = 1800 RPM (60 Hz) Default injury or loss of life.