Fluid detection
Sensor 6.620 at port 6 of the IO link gateway is used to detect the fluid.
If the sensor is not present, the value -999 is output. If the sensor measures an
invalid value, -999 is output as well and warning B328 is issued.
The value of the detected fluid is output in P-0-1274.
Table 11: Parameters for fluid detection
Function
Table 12: Sensors
Sensors
Pressure sensor
Filling level sensor
Temperature sensor
Pressure filter contamination sensor
Leakage flow sensor
Leakage temperature sensor
Water content sensor
Air inclusion sensor
Dirt particle sensor
Drip pan leakage sensor
Parameter
Description
P-0-1274
Actual value
P-0-1389[12]
Switch-on threshold
P-0-1389[41]
Debouncing time
Warning
P-0-1389[42]
Oil
Warning
P-0-1389[43]
Mixture
Warning
P-0-1389[44]
Water
Standard (included in the
scope of delivery)
Product information 31/128
Unit
Bytes
Decimal
%
4
%
4
ms
4
%
4
%
4
%
4
Optional
X
X
X
X
CytroBox, RE 51057-B/11.19, Bosch Rexroth AG
Default
points
1
-
3
-
3
-
3
8
3
25
3
70
X
X
X
X
X
X