Panasonic HM500 Series Instruction Manual
Hide thumbs Also See for HM500 Series:

Advertisement

Quick Links

ACGM0194V3EN Version 3.0
2023.01
https://industry.panasonic.eu
Touch Terminals
HM500 Series
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic HM500 Series

  • Page 1 Touch Terminals HM500 Series Instruction Manual ACGM0194V3EN Version 3.0 2023.01 https://industry.panasonic.eu...
  • Page 2 This manual and everything described in it are copyrighted. You may not copy this manual, in whole or part, without written consent of Panasonic. Please direct support matters and technical questions to your local Panasonic representative. Distributed by Panasonic Industry Europe GmbH https://industry.panasonic.eu...
  • Page 3: Table Of Contents

    Table of contents Introduction ............................... 4 Important symbols ............................ 4 Special instructions for use ........................5 Standards and approvals ......................... 5 Product overview ............................6 Product identification ..........................6 Technical data common to all models ..................... 7 Hardware specifications ........................7 Environmental conditions ........................
  • Page 4: Introduction

    Introduction Introduction This instruction manual contains information about the installation, transportation, storage, assembly, use and maintenance of touch terminals of the HM500 series. The following models are available: HM504 Touch terminal with 4.3” TFT color widescreen display touchscreen HM507 Touch terminal with 7” TFT color widescreen display touchscreen HM510 Touch terminal with 10.4”...
  • Page 5: Special Instructions For Use

    Special instructions for use Special instructions for use • Install the product according to the accompanying installation instructions. • Ground the product according to the accompanying installation instructions. • Only qualified personnel may install or repair the product. • The product must be cleaned only with a soft cloth and neutral soap product. Do not use solvents. •...
  • Page 6: Product Overview

    They are the ideal choice for all demanding HMI applications including factory and building automation. The HM500 series touch terminals have been designed to run the software HMWIN Studio. • HMWIN runtime included. Full compatibility with HMWIN Studio.
  • Page 7: Technical Data Common To All Models

    Technical data common to all models Technical data common to all models Hardware specifications Touchscreen technology Resistive 3V, 50mAh lithium, rechargeable, not user-replaceable, Real-time clock back-up battery model VL2330 Fuse Automatic 128MB (HM504, HM507) Flash memory 256MB (HM510) Recipe memory (Flash memory storage limited only by available memory) Real-time clock Clock/calendar with back-up battery Accuracy real-time clock (at 25°C)
  • Page 8: Electromagnetic Compatibility (Emc)

    Technical data common to all models Electromagnetic compatibility (EMC) Radiated disturbance test Class A EN 55011 8kV (air electrostatic discharge) Electrostatic discharge immunity EN 61000-4-2 test 4kV (contact electrostatic discharge) 80MHz–1GHz, 10V/m Radiated, radio frequency, 1.4–2GHz, 3V/m EN 61000-4-3 electromagnetic field immunity test 2–2.7GHz, 1V/m ±2kV DC power port Burst immunity test...
  • Page 9: Viewing Angles

    Technical data common to all models Viewing angles The viewing angles for the horizontal (L, R) and vertical (U, D) axes are specified in reference to the vertical axis of the display. The viewing angles always refer to the standard mounting orientation. For the viewing angle values (U, D ,L, R), refer to the technical data of the respective touch terminal model.
  • Page 10: Technical Data By Model

    Technical data by model Technical data by model HM504 HM507 HM510 Display / Backlight TFT color / LED Colors Resolution (pixel) 480 x 272 800 x 480 800 x 600 Brightness 150cd/m² typ. 300cd/m² typ. Display size (inch) 4.3” widescreen 7”...
  • Page 11: Product Dimensions

    Product dimensions Product dimensions HM504 Cutout 149mm 109mm 136mm 96mm 56mm ACGM0194V3EN Version 3.0...
  • Page 12: Hm507, Hm510

    Product dimensions HM507, HM510 Cutout Model HM507 187mm 147mm 176mm 136mm 47mm HM510 287mm 232mm 276mm 221mm 56mm ACGM0194V3EN Version 3.0...
  • Page 13: Unpacking And Packing Instructions

    Unpacking and packing instructions 10. Unpacking and packing instructions To repack the product, please follow the instructions backwards. 11. Installation 11.1 Installation environment The product is not intended for continuous exposure to direct sunlight. This might accelerate the aging process of the front panel film. The product is not intended for installation in contact with corrosive chemical compounds.
  • Page 14: Applying The Gasket

    Installation 11.2 Applying the gasket The gasket should be applied on the rear of the frame. HM504, HM507 HM510 (1) Gasket (2) Installation cutout 11.3 Installation procedure For details on installation, please refer to the “Installation Guide” provided with the product. Place the fixing brackets as shown in the following figure.
  • Page 15: Connections

    Connections 12. Connections 12.1 HM504 (1) Serial port (2) Power supply (3) USB port (4) 2x Ethernet port (5) Expansion slot for plug-ins (6) SD card slot ACGM0194V3EN Version 3.0...
  • Page 16: Hm507, Hm510

    Connections 12.2 HM507, HM510 (1) (2) (1) Serial port (2) 2x Ethernet port (3) Power supply (4) 2x USB port (5) 2x expansion slot for plug-ins (6) SD card slot ACGM0194V3EN Version 3.0...
  • Page 17: Serial Port

    Connections 12.3 Serial port The serial port is used to communicate with the PLC or with another type of controller. Standards available for the signals in the PLC port connector are: RS232, RS422, RS485. Use the corresponding communication cable for the connection. The serial port is software programmable.
  • Page 18: Optional Plug-Ins

    Connections 12.5 Optional plug-ins There are two optional plug-ins available for the HM500 series. Depending on the touch terminal type, there are one or two expansion slots. Slot #2 and slot #4 are available only if the plug-in module is equipped with the bus extension connector.
  • Page 19: Power Supply, Grounding, And Shielding

    Connections 12.6 Power supply, grounding, and shielding The power supply terminal block is shown in the following figure. +24V Common M NOTE Make sure that the power supply has sufficient power capacity for the operation of the product. The product must always be grounded to earth. Grounding helps limit the effects of noise due to electromagnetic interference on the control system.
  • Page 20: Battery

    Battery 13. Battery The touch terminals are equipped with rechargeable lithium batteries that are not user-replaceable. The battery is needed to keep the real-time clock running (date and time). When the touch terminal is installed for the first time, the battery must be charged for 48 hours. When the battery is fully charged, data backup at 25°C is guaranteed for 3 months.
  • Page 21: Getting Started

    Getting started 15. Getting started The HM500 series touch terminals must be programmed with the programming software HMWIN Studio, a Windows application. There are two options to transfer an HMWIN application project to a touch terminal: Ethernet Connect the touch terminal via the Ethernet interface to a personal computer running the HMWIN Studio software.
  • Page 22: Record Of Changes

    Record of changes 17. Record of changes ACGM0194V3EN, January 2023 • Deleted the chapter “System settings tool” • Deleted model HM513 • Added the chapters “Important symbols”, “Special instructions for use”, “Disposal” • Updated the chapter “Standards and approvals” • Updated company name and back page •...
  • Page 23 Panasonic Industry Europe GmbH Caroline-Herschel-Strasse 100, 85521 Ottobrunn, Germany +49 89 45354-1000 https://industry.panasonic.eu January 2023...

This manual is also suitable for:

Hm504Hm507Hm510

Table of Contents