Exodraft EFC18 Manual
Hide thumbs Also See for EFC18:

Advertisement

Quick Links

Controls
EFC18
UK
| Read and save these instructions!
Your energy. Optimized.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EFC18 and is the answer not in the manual?

Questions and answers

Summary of Contents for Exodraft EFC18

  • Page 1 Controls EFC18 | Read and save these instructions! Your energy. Optimized.
  • Page 3: Table Of Contents

    Your energy. Optimized. Control | EFC18 Content Product information Scope of supply Accessories Technical specifications Construction and components Installation Installation instructions Settings Daily use UK Conformity Assessed Declaration of Conformity...
  • Page 4 How to use this manual This manual has been prepared based on the specific product and contains relevant technical information and installations guides. Accessories and spare parts are not covered by this manual. Please refer to the individual manuals of these components. This installation manual does not contain any system design documentation.
  • Page 5 Symbols The following symbols may be used in the manual to draw attention to danger or risk of personal injury or damage to the product. General prohibition Failure to observe instructions marked with the prohibited symbol may result in extreme danger or serious personal injury. General attention Marks a dangerous situation that, in the worst-case scenario, can cause serious personal injury or significant damage to the product.
  • Page 6 Prior to servicing the product, disconnect the power and ensure that it cannot accidentally be reconnected. • Exodraft always recommends the use of a smoke alarm when a solid fuel open fire is installed. • If the Exodraft fan system has been designed for solid fuel/multi fuel installations, please ensure that the design meets the requirements of BS EN15287-1.
  • Page 7: Product Information

    3112016_EFC18_UK Product information Exodraft control EFC18 is, like the Exodraft chimney fan, designed to be used with fire places, stoves and boilers for solid fuel. Using the temperature sensor, the control unit can stop and start the chimney fan automatically.
  • Page 8 Your energy. Optimized. Warranty All Exodraft products are covered by a 2-year guarantee as per European consumer rights legislation. For some countries an extended period of guarantee may apply depending on either national legislation or other clearly stipulated conditions. Customer complaints must be handled by a specialised dealer or who- lesaler (preferably where the Exodraft product has been bought originally).
  • Page 9: Technical Specifications

    3112016_EFC18_UK Technical specifications The Exodraft EFC18 flue gas control is a 9-speed control with integrated temperature monitoring for safety switching and automatic start/stop of the chimney fan. The control also has a start function for producing a stronger chimney draught to ensure easy lighting. The EFC18 control comprises control console and tempe- rature sensor for mounting under the chimney fan.
  • Page 10: Construction And Components

    Your energy. Optimized. Construction and components EFC18 Temperature sensor Installation EFC18 • To separate the panel, first remove the frame. • There are two screws at the back of the frame which hold the panel in place on the base.
  • Page 11 3112016_EFC18_UK Temperature sensor • Fit the sensor to the base plate of the chimney fan. • The sensor should be positioned. See picture below If an FRx-AFD flange is used, remove the plug from the pipe If an FRx-AFD flange is used, remove the plug from the pipe and insert the sensor.
  • Page 12: Installation Instructions

    Your energy. Optimized. Installation instructions Connect the EFC18 and the temperature sensor as in the diagram below (RS/RSV). Connect the EFC18 and the temperature sensor as in the diagram below (RSHT). Always switch off the electricity supply before opening the control unit.
  • Page 13: Settings

    3112016_EFC18_UK Settings The EFC18 is set initially so that the temperature sensor starts and stops the chimney fan at either 20 °C, 40 °C or 80 °C. The factory setting is 40 °C. Setting the temperature Step Action The control must be standby (shows ”–” in display).
  • Page 14: Uk Conformity Assessed

    UK Conformity Assessed UK Conformity Assessed Exodraft a/s Industrivej 10 DK-5550 Langeskov Hereby declares that the following products: EFC18 Were manufactured in conformity with the provisions of the following regulations: The Supply of Machinery (Safety) Regulations 2008 Electrical Equipment (Safety) Regulations 2016...
  • Page 15: Declaration Of Conformity

    EU-Vaatimustenmukaisuusvakuutus Déclaration de conformité de l’Union Européenne ESS-Samræmisstaðfesting EU-Samsvarserklæring Dichiarazione di Conformità Unione Europea EU Deklaracja zgodności Exodraft a/s Industrivej 10 DK-5550 Langeskov Erklærer på eget ansvar, at følgende produkter: Veklaart dat onderstaande producten: Hereby declares that the following products: Deklarerar på...
  • Page 16 DK: Exodraft a/s Industrivej 10 DK-5550 Langeskov Tel: +45 7010 2234 Fax: +45 7010 2235 info@exodraft.dk www.exodraft.dk SE: Exodraft a/s Kalendevägen 2 SE-302 39 Halmstad Tel: +46 (0)8-5000 1520 info@exodraft.se www.exodraft.se NO: Exodraft a/s Storgaten 88 NO-3060 Svelvik Tel: +47 3329 7062 info@exodraft.no...

Table of Contents