VC4, VC6, VC8 E n g i n e e r i n g O p e r a t i o n & Series METAL Pumps Saniflo ™ M a i n t e n a n c e R e f i n e y o u r p r o c e s s WIL-12120-E-01...
T A b L E o F c o n T E n T s Section 1 cAuTions—REAd FiRsT! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Section 2 WiLdEn PuMP dEsignATion sysTEM .
S e c t i o n 1 c A u T i o n s — R E A d F i R s T ! TemperaTure LimiTs: CauTiON: Always wear safety glasses when operat- Buna-N –12.2°C to 82.2°C 10°F to 180°F ing pump.
S e c t i o n 2 W i L d E n P u M P d E s i g n A T i o n s y s T E M sAniFLo LEgEnd VCX / X X / XX / XX / xxxx gAskETs sPEciALTy...
Page 5
S e c t i o n 3 H o W i T W o R k s — P u M P The Saniflo™ VC pump is an air operated, positive displacement, electrically controlled pump. These drawings show the flow pattern through the pump upon its initial stroke.
S e c t i o n 4 d i M E n s i o n A L d R A W i n g s s A n i F L o DIMENSIONS – SaNIflO™ VC ITEM METRIC (mm) STaNDaRD (inch) METRIC (mm) STaNDaRD (inch)
Page 7
S e c t i o n 5 s u g g E s T E d i n s T A L L A T i o n the pipe size should be at least the size of the inlet and eLeVAtION: selecting a site that is well within the pump’s discharge ports of the pump or larger if highly viscous dynamic lift capability will assure that loss-of-prime...
Page 8
S e c t i o n 5 s u g g E s T E d o P E R A T i o n & M A i n T E n A n c E the adjustable probe the plc: During operation, certain products can coat the sensor probe creating false inputs to the control panel and...
Page 9
s u g g E s T E d i n s T A L L A T i o n the next screen contains the probe set point value . remain stopped and the alarm will be displayed until the using the numeric keys, enter the new value you condition is corrected and the pump control is reset .
Page 10
S e c t i o n 5 T R o u b L E s H o o T i n g thick products or high pumping volumes may require seated properly and no air is leaking . you to increase the discharge pressure . the discharge Align check valve(s) hinge at top of tee .
Page 11
S e c t i o n 6 A s s E M b L y T o o l s R e q u i r e d : caution: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump .
Page 12
d i s A s s E M b L y / R E A s s E M b L y pump maintenance checKlist pump cleaning procedure CHECK DAILY: empty the discharge piping of product using the purge switch on the control panel . Check regulator pressure * suction = Approx .
Page 13
S e c t i o n 5 d i s A s s E M b L y / R E A s s E M b L y locKout-tag out procedure Let others in the area know you are locking the machine out .
S e c t i o n 8 E x p L o d E d V i E w & p A r T s L i s T i n g Vc puMp conTroLLEr E x p L o d E d V i E w WILDEN PUMP &...
Page 21
E x P L o d E d V i E W & P A R T s L i s T i n g Vc PuMP conTRoLLER P A R T s L i s T i n g iTEM PART no.
Page 22
S e c t i o n 8 V c P u M P c o n T R o L L E R s c H E M A T i c WILDEN PUMP & ENGINEERING CO., LLC WIL-12120-E-01...
Page 23
W a r r a n t y Each and every product manufactured by Wilden Pump and Engineering, LLC is built to meet the highest standards of quality. Every pump is functionally tested to insure integrity of operation. Wilden Pump and Engineering, LLC warrants that pumps, accessories and parts manufactured or supplied by it to be free from defects in material and workmanship for a period of five (5) years from date of installation or six (6) years from date of manufacture, whichever comes first.
Page 24
Advance Your Process Enrich Your Process Advanced wetted path designs Simplicity of design Lower the cost of operation Unique Technology Maximize product containment Reliable, leak-free & quiet Longer MTBF Validated & certified (Mean Time Between Failures) Enhanced internal clearance Intrinsically safe The result of advanced thought The result of unique thought Refine Your Process...