Operating methods

Description of functions
Setting of timer off
Setting of timer on
AUTO mode
CONTINUOUS mode
DRYING function in dehumidifier
EN
When the dehumidifier is running, press the [Timer key] to adjust time from 1h
to 24h, pressing the key once to increase the setting time by 1h, after the setting
time exceeds 24h, the figure returns to 1 to start cycle. The Timer key can also
be pressed all the time, the time increases and changes circularly, when the set
time expires, the dehumidifier turns off automatically. After the setting is
completed, if the Timer key does not act at all within 5s, the set time is
confirmed. In timer off state the key lamp on the [Timer key] is normally on.
When the dehumidifier is in standby state, the method for adjustment of setting
time by the [Timer key] is the same as timer off. After the setting is completed,
if the Timer key does not act at all within 5s, the set time is confirmed. In timer
on state the key lamp on the [Timer key] is normally on, and the set time is
displayed on controlpanel.
Select AUTO dehumidification, if the room humidity is high than the set
humidity or is between +5% or -5% of the set humidity , the compressor will
starts and the fan will run at the set speed. If the room humidity is lower than the
set humidity by -5%, then the compressor will stop but the fan will run at the set
speed. The default set humidity value is 50%.
Select CONTINUOUS dehumidification, no matter how the relative humidity in
the room is, the compressor starts, the fan runs at high speed in default, and the
air speed can be regulated via the air speedkey.
Press the Drying key in dehumidifier to start drying in the duhumidifier to
prevent inner unit mildew .