Technical specifications
Article number
Controller
Counting and measuring
Ambient temperature during operation
Ambient temperature during
storage/transportation
50
–
per positioning axis
–
per synchronous axis
–
per external encoder
–
per output cam
per cam track
–
–
per probe
Number of available Extended Motion
•
Control resources for technology objects
•
Required Extended Motion Control
resources
–
per cam (1 000 points and 50 seg
ments)
–
per cam (10 000 points and 50 seg
ments)
–
for each set of kinematics
Per leading axis proxy
–
•
Positioning axis
Number of positioning axes at motion
–
control cycle of 4 ms (typical value)
–
Number of positioning axes at motion
control cycle of 8 ms (typical value)
•
PID_Compact
•
PID_3Step
•
PID-Temp
•
High-speed counter
Standards, approvals, certificates
Suitable for safety functions
Ambient conditions
horizontal installation, min.
•
•
horizontal installation, max.
•
vertical installation, min.
vertical installation, max.
•
•
min.
6ES7518-4TP00-0AB0
80
160
80
20
160
40
512
2
20
30
3
140
192
Yes; Universal PID controller with integrated
optimization
Yes; PID controller with integrated optimization
for valves
Yes; PID controller with integrated optimization
for temperature
Yes
No
0 °C
60 °C; Display: 50 °C, at an operating temperature
of typically 50 °C, the display is switched off
0 °C
40 °C; Display: 40 °C, at an operating temperature
of typically 40 °C, the display is switched off
-40 °C
CPU 1518T-4 PN/DP (6ES7518-4TP00-0AB0)
Equipment Manual, 11/2022, A5E50479758-AB