Download Print this page

Installation And Setting - Pilz PSEN op3.1 Operating Manual

Advertisement

PSEN op3.1/3.2
a Wire the outputs from the transmitter to the inputs provided on a safety light grid or con-
trol system for external muting sensors.
Transmitter
Assignment of the 4-pin
M12 male connector

Installation and setting

General
}
Torque setting: Please note the information provided under
If necessary, the connector plug block can be rotated by 180°.
Pull the retention spring in the direction of the con-
nector (see diagram, [1]) and rotate the connector plug
block by 180°.
Setting
1. Set the sensitivity controller on the receiver to the highest level.
2. Position the transmitter and receiver on the muting sensor opposite each other in paral-
lel, in the required position in relation to the light grid. In both positions, a mounting sur-
face must be available, to which the transmitter and receiver can be attached.
3. Move the transmitter and receiver horizontally and vertically until the orange LED illu-
minates and then goes out. Attach the transmitter and receiver in the middle between
these points.
}
If the muting sensors are to detect small objects, the sensitivity of the receiver can be
reduced.
Operating Manual PSEN op3.1/3.2
1003607-EN-02
2
3
INFORMATION
The sensitivity controller can be rotated by a maximum of 240°.
If the trimmer is overwound the product will be destroyed.
– Never rotate the trimmer beyond the maximum position.
PIN
Function
1
1:
+10 ... 30 VDC
2:
Test +
3:
0 V
4:
Test -
4
Technical details [
Wire colour
brown
white
blue
black
8].
[1]
6

Advertisement

loading

This manual is also suitable for:

Psen op3.2