Download Print this page

Pilz PSEN op3.1 Operating Manual page 5

Advertisement

PSEN op3.1/3.2
Unit viewer: receiver
[2]
[5]
Connector plug block rotated on the back of
the unit
}
[1]: LEDs for status display (on transmitter only)
}
[2]: LED to display operating status
}
[3]: Control for setting the sensitivity
}
[4]: Retention spring for releasing the rotatable connection
}
[5]: Slot (through hole) for attachment and horizontal adjustment
}
[6]: Through hole for attachment
}
[7]: Through hole for attachment
}
[8]: Rotatable connector plug block
Wiring
}
Information given in the
}
Use copper wiring with a temperature stability of 55 °C.
}
The supply voltage must be provided from a power supply. Use a protection class II
power supply in accordance with the regulations for extra low voltages with safe separ-
ation.
a Wire the outputs from the receiver to the inputs provided on a safety light grid or control
system for external muting sensors.
Receiver
Assignment of the 4-pin
M12 male connector
Operating Manual PSEN op3.1/3.2
1003607-EN-02
[1]
[3]
[7]
[4]
Technical details [
[1]
[2]
[6]
[5]
[8]
Connector plug block rotated on the bottom
of the unit
8]
must be followed.
PIN
2
1
1:
2:
3:
4:
3
4
[3]
[7]
Function
Wire colour
+10 ... 30 VDC
brown
Output NC
white
0 V
blue
Output NO
black
[6]
[4]
[8]