This manual contains text, diagrams and explanations which will guide the reader in the correct
installation, safe use and operation of the FX
-232-BD (hereafter abbreviated to "232BD") and should be
2N
read and understood before attempting to install or use the unit. Further information can be found in the
associated manuals mentioned below.
Specifications are subject to change without notice
Safety guidelines for the user and protection of the FX
This manual has been written to be used by trained and competent personnel. The definition of such a
person or persons is as follows:
a) Any engineer using the product associated with this manual, should be of a competent nature,
trained and qualified to the local and national standards. These engineers should be fully aware of
all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and qualified to
the local and national standards.
c) All operators of the completed equipment should be trained to use this product in a safe and
coordinated manner in compliance to established safety practices.
Note: The term 'completed equipment' refers to a third party constructed device which contains or uses
the product associated with this manual.
Notes on the Symbols Used in this Manual
At various times throughout this manual certain symbols will be used to highlight points of information
which are intended to ensure the users personal safety and protect the integrity of equipment.
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and property
damage.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for the actual use of
the product based on these illustrative examples.
Please contact a Mitsubishi distributor for more information concerning applications in life critical
situations or high reliability.
Associated Manuals
PROGRAMMING MANUAL ΙΙ, or FX Series User's Manual - Data Communication Edition mentioned
below are not provided in sets with a product.
Contact our agent where the product was purchased to request the manuals accordingly
Manual name
Manual No.
FX Series User's
Describes contents related to communication available
Manual - Data
in FX Series PLC such as wiring, communication
JY997D16901
Communication
setting and program examples.
Edition
(Make sure to read this manual.)
FX
Series
Describes contents related to hardware of FX
2N
JY992D66301
Hardware Manual
PLC such as specifications, wiring and installation.
FX Programming
Describes instructions in FX
JY992D88101
Manual II
Series.
★ Indispensable manual
This manual describes the installation and specifications of the 232BD.
For details on wiring with communication equipment, system configuration and communication setting, and program
examples, refer to the "FX Series User's Manual - Data Communication Edition".
1. Outline of Product
The 232BD is an RS-232C communication board with a 9-Pin D-Sub. It is an insulated unit for signal
exchange. Connected to the main unit of the FX
it enables serial data transfer between the PLC and equipment via an RS-232C port.
1.1 Communication Functions and Applicable PLC
(Available in indicated version or later)
Communication
-232-BD
2N
type
Computer link
USER'S GUIDE
No protocol
communication
JY992D63201E
Optional
programming port
Remote
maintenance
1.2 Outside dimensions and name of each part
-232-BD.
2N
35(1.38")
The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows the
pin arrangement.
1
6
2
7
3
8
4
9
5
1.3 System configuration
Description
Only one function expansion board can be used for one main unit of FX
FX
-232-BD cannot be used by the plural. Other expansion boards cannot be used together with
2N
FX
-232-BD. For the system configuration, refer to the FX Series User's Manual - Data Communication
2N
Edition offered separately.
Series
2N
2. Installation
Caution
/FX
/FX
/FX
1S
1N
2N
2NC
• Use in the environments specified under the general specification in the manual.
Do not use the product in environments with excessive or conductive dust, corrosive or
flammable gas, oily smoke, moisture or rain, excessive heat, regular impact shocks or
excessive vibration, as it may result in electrical shock, fire, malfunction, damage or
deterioration on the product.
• Make sure to shut off the power outside the product before installing or wiring it.
Otherwise, electric shock or serious damage to on the product may occur.
• Never drop wire chips or shavings into the vent slits when drilling screw holes or performing
wiring, as they may cause fire, breakdown, or malfunction.
Securely install the 232BD to the designated port.
Poor connection may cause malfunction.
Series PLC,
2N
FX
Function
2N
Data transfer via link protocol between PLC and computer
V1.06
(specified as the master station).
Serial communication without protocol between PLC and equipment via RS-232C
V1.06
interface.
First
Optional port available for suitable programming tool when 232ADP is connected to
product
PLC.
First
Program transfer or monitoring enabled via modem and phone line connected to serial
product
port of PLC.
Unit: mm (inches)
1
2 3
Mounting hole (2-φ3.5)
4
6
RXD LED: Lit during receive.
TXD LED: Lit during send.
Connector for RS-232C equipment
The top face of this connector is higher than the top face
5
of the PLC panel cover by approximately 7 mm (0.27").
1
Hole for connector fixing screw (#4-40UNC)
Connector for PLC
Accessories: Top cover for board 1
M3 screw to mount board 2
M3 screw to fix top cover 1
Pin No.
Signal
Name
Function
Receive carrier
Turns ON when carrier for data
1
CD
detection
receive is detected.
Receive data
Receive data
2
RD(RXD)
(RS-232C equipment → 232BD)
input
Send data
3
SD(TXD)
Send data input
(232BD → RS-232C equipment)
Turns ON when RS-232C equipment
4
ER(DTR)
Send request
becomes ready for receive.
5
SG(GND)
Signal ground
Signal ground
Turns ON when send request is given
6
DR(DSR)
Send enabled
to RS-232C equipment
7,8,9
Not used
.
2N
2.1 Installation procedure
Turn OFF the power of the programmable controller, and mount the 232BD using the following procedure.
Remove the panel cover from the top face of the main unit.
Connect the 232BD to the board mounting connector provided on the
base unit.
Fix the 232BD to the main unit using the M3 self-tapping screws
provided, fitting the mounting bracket and the round crimp-style terminal
with the ground cable as shown in the figure on the right.
Make sure that the crimp-style terminal is attached in the direction
shown in the figure on the right, and that the ground cable extends from
the unit shown in the figure below.
Tightening torque: 0.3 to 0.6 N m
For M3(0.14")
Grounding
Cable
16mm(0.63") or less
Cut out the hole provided on the left portion of the panel cover using a tool such as nippers and cutter
so that the terminal block can be seen. The top face of this connector is higher than the top face of the
panel cover of the programmable controller by approximately 7 mm (0.27").
3. Specifications
3.1 Environmental specifications
The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of the
PLC main unit.)
3.2 Power supply specifications
5V DC, 20 mA is supplied as the power from the PLC.
3.3 Performance specifications
Item
Description
Transmission standard
In conformance to RS-232C
Maximum transmission
15 m (49ft) maximum
distance
External equipment
D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-
connection method
2A3A (#4-40UNC, inch screw thread type)
Indication (LED)
RXD, TXD
Full-duplex (When the version of PLC(FX
Communication method
Half-duplex (When the version of PLC(FX
Communication
Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4
procedure
procedure, protocol for programming tool
Following baud rate can be specified when using computer link or no
Baud rate
protocol communication: 300/600/1200/2400/4800/9600/19200 bps
Insulation
Not insulated
4. CAUTION FOR USE
1) When programming tool is connected the 232BD, do not use any other communication format or
parameters. If communication format or parameters is set, programming is not possible.
2) Only one programming tool (such as FX-10P , FX-20P , etc.) should be connected to either the pro-
gramming port or the port provided on the 232BD. If a programming tool is connected to both connec-
tors, the following may occur.
a) The program inside the programmable controller may not be consistent with the program inside
the programming tool. If the program is modified or the set value for the timer or the counter is
modified, a part of the program may be damaged and the programmable controller may
malfunction.
b) When the sampling trace function of the programmable controller is used from both ports, the
correct sampling trace result cannot be obtained.
Manual number : JY992D63201
Manual revision : E
Date
: AUGUST 2006
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any
patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving
industrial property rights which may occur as a result of using the contents noted in this manual.
HEAD OFFICE
: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
HIMEJI WORKS
: 840, CHIYODA CHO, HIMEJI, JAPAN
232BD
) is Ver. 2.00 or later) /
2N
2N
) is earlier than Ver. 2.00)

Advertisement

loading