Advertisement

Available languages

Available languages

INSTRUCTIONS

INSTALLATION, USE AND MAINTENANCE

- Warning! Security of the fitting is guaranteed only with the appropriate use of the
following instructions: therefore it is necessary to preserve them.
- Warning! Before connecting to the main network, during assembly or
replacement of the product, make sure to disconnect the tension.
- Warning! The product has to be repaired only by professional technicians or by the
manufacturer.
- During product installation respect carefully the plant rules.
- In case of cracks or damages the screen should be immediately replaced.
- For any replacement contact the manufacturing company.
- The fitting must be installed by a professional electrician.
- The fitting cannot be modified or tampered with in any way, any modification may
compromise security by making it dangerous. The manufacturer declines any
responsibility for the modified products. Class I fitting must be connected to the
ground circuit of the electrical plant.
- Keep at least 1 m between the fitting and the illuminated surface.
- Fitting suitable for outdoor applications. Protection degree IP65.
- Fitting suitable for direct mounting on normally inflammable surfaces.
- Remove the wall mounting flange by unscrewing the n° 2 side screws.
- Install the wall fixing flange using n°2/3 fischer, with a minimum diameter of 6 mm.
- Make sure that the fixing flange is securely connected to the wall (fig. A).
- Connect the power cables to a triple connector that can guarantee a minimum
protection degree IP67 (fig.B). Lanzini provides this connector (code
LKITA00000000003) as a separate mounting kit, on request; alternatively, you can
use a similar connector. The fitting is supplied with a cable looped and pulled. You
can connect it to the network using a connection system that guarantees the IP 67 or
higher (IP box, etc.).
- Position the fitting with the required inclination using the appropriate goniometer
placed on the bracket, and tighten the screws previously removed (fig. D).
e sure you have done everything correctly and reconnect the tension (fig. D).
- Warning! Risk of electric shock
- For use in environments where an accumulation of non-conductive dust on the
luminaire
Power supply: 220-240 V AC - 50/60 HZ
Insulation class: I
Operating temperature: -30° +45°C
Power

Weight

Dimensions

Surface exposed to the wind

30 W
1,23 Kg
233×211×37 mm
0,032 m²
45 W
1,23 Kg
233×211×37 mm
0,032 m²
50 W
1,23 Kg
233×211×37 mm
0,032 m²
EN
1 m
0,006 m²
0,006 m²
0,006 m²
EP s.p.a. Via del Commercio 1 - 25039 - Travagliato (BS) - ITALY
MODEL
QM
IP66
IT-Questo prodotto contiene una sorgente luminosa di efficienza energetica classe
EN-This product contains a light source of energy efficiency class
P06013100
OUTDOOR
D
www.lanzini.it

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QM and is the answer not in the manual?

Questions and answers

Summary of Contents for LANZINI QM

  • Page 1 - Make sure that the fixing flange is securely connected to the wall (fig. A). - Connect the power cables to a triple connector that can guarantee a minimum protection degree IP67 (fig.B). Lanzini provides this connector (code LKITA00000000003) as a separate mounting kit, on request; alternatively, you can use a similar connector.
  • Page 2 - Assicurarsi di aver fissato correttamente al muro la flangia di fissaggio (fig. A). - Collegare i cavi di alimentazione ad un connettore tripolare in grado di garantire un grado di protezione minimo IP67 (fig.B). Lanzini fornisce tale connettore (cod. LKITA00000000003) come kit di montaggio separato, su richiesta; in alternativa è...

Table of Contents