OPERATING INSTRUCTIONS
CHECKING FOR THE PRESENCE OF AC VOLTAGE
1. Prior to use, test on a known live cir
functionality.
2. Place NCV Antenna
near an AC voltage sour
7
present, the unit will emit audible beeps and the NCV Indicator
will illuminate.
SILENT MODE
With the NCVT-6 powered off, press and hold the On/Off Button
five seconds (the NCV On/Off
for NCV mode, or the LDM Control
1
Button
2
for LDM mode) to power-on in Silent mode. While Silent
mode is active, the silent mode icon
indicators and display readings will continue to function as normal,
but no audible indicators will be given. Silent mode will remain active
until the NCVT-6 is powered-off.
AUTO-POWER OFF (APO)
While the NCV function is active, the display
following 15 seconds of no voltage detection (the NCV indicator
will remain illuminated). After 4 minutes of further inactivity
NCVT-6 will automatically power-off.
While the LDM function is active, the NCVT
power-off following 15 seconds of inactivity.
MAINTENANCE
BATTERY REPLACEMENT
When the Battery Status Indicator
the LDM functionality will be disabled, and the NCV functionality has less
than 8 hours remaining. At this point, the batteries should be replaced:
1. Unscrew Battery Cap
and remove/recycle spent batteries
11
2.
Install two new AAA batteries
10
3.
Screw battery cap until fully seated to ensure a tight seal, being careful
not to damage the O-ring
. NOTE: Damage to the O-ring can affect
9
the IP40 dust resistant rating, but will not affect functionality.
CLEANING
Be sure tester is turned off and wipe with a clean, dr
cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when not in use for a prolonged period
of time. Do not expose to high temperatures or humidity
a period of storage in extreme conditions
mentioned in the General Specifications section, allow the tester to
return to normal operating conditions before using.
DISPOSAL
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations.
www.calcert.com
15
10
20
5
25
0
30
cuit to verify tester
ce. If voltage is
5
for
will be displayed. All visual
H
will powersdown
4
5
, the
-6 will automatically
shows only one bar remaining,
F
.
10
. Note proper polarity
.
y lint-free
. After
exceeding the limits