Osdp Reader Wiring; Wiring Of Monitored Input; Leds - Siemens MFI Technical Manual

Table of Contents

Advertisement

Connections and LEDs
6

OSDP Reader wiring

6.2 OSDP Reader wiring

6.3 Wiring of monitored input

6.4 LEDs

12 | 18
Reader connection via OSDP with or without encryption. The readers should be
connected to the appropriate terminal blocks (A, B, -, +) of the READER port
Mapping from MFI board to the Reader ports.
Up to 8 OSDP readers can be daisy chained (from one reader to another) on the
same connection.
Labels on
A
MFI board
Labels on the
GPIO 1
Reader ports
A
(HID,
Vanderbilt
Readers)
1. Connect the shielding to the housing earth.
2. Insulate the shielding at the input (e.g. door contact), do not connect it.
3. DC: door contact
4. R: terminating resistors each 22 kOhm
LED function
RLY 1
RLY 2
RLY 3
Status LEDs
Indicates
RLY 4
activated/deactivated
AUX OUT 1
AUX OUT 2
AUX OUT 3
AUX OUT 4
INPUT status LEDs
Restricted
B
-
GPIO 2
GND
B
-
Name on the board
Color of LED
H715
White
H716
White
H717
White
H718
White
H719
White
H720
White
H721
White
H722
White
H700 to H707
Red (During tamper)
Green (Normal)
Orange (Alarm)
+
+VDC
+
A6V12068740
2020-09-07