Clearances - Empire Comfort Systems VFP32FB Series Installation Instructions And Owner's Manual

Premium vent-free universal fireboxes
Table of Contents

Advertisement

Sidewall Clearances: The clearance from the inside of the firebox
to perpendicular combustible side wall should not be less than
6 inches. See Figure 1.
Firebox Side and Back Clearances: The firebox outer casing side
and back flanges are zero clearance to combustibles.
Top Framing and Finishing: Combustible finishing materials
requires 3/4 inch to top of unit. There are two shoulder bolts
attached to the unit to maintain the minimum clearance. See
Figure 2.
Page 4

CLEARANCES

Figure 1
Figure 2a - Louvered Models
Figure 2b - Flush Models
33742-6-1217