OPTIONAL FRESH AIR KIT INSTALLATION INSTRUCTIONS

The optional Fresh Air Kit is designed to introduce outside air to
the firebox as desired.
It must be installed prior to, or at the time of firebox installation to
framing.
The Fresh Air kit must be installed prior to the installation of wall-
board or other finishing materials around the unit.
Hardware needed (not provided): 4 inch Aluminum Flex Duct,
2 Band Clamps
Tools needed: Gloves, Metal snips, 5/16 inch Nut Driver,
Phillips Screwdriver
CAUTION: Sharp edges
Slide Assembly Installation
1. Begin by removing the rectangular cutout located on the left
side of the unit. Use gloves and sheet metal snips to create
the opening for the Air Door assembly to install into.
See Figure 13.
2. Bend the tab out of the way. See Figure 14.
Page 10
Figure 13
Figure 14
3. Insert Slide Assembly through the cut-out as shown in Figure
15. Before you fasten ensure that the handle penetrates the
inner firebox wall. See Figure 16. Fasten the Slide Assembly
with the four 10 x 1/2 Hex Head Screws provided.
Figure 15
Figure 16
33742-6-1217