Honeywell Ex-Or MSB1001DT Installation And Commissioning Instructions page 2

Ip65 battenfit sensor with regulating photocell for use with dsi/dali ballasts

Advertisement

IP65 BattenFit Sensor with Regulating Photocell: MSB1001DT - for use with DSI ballasts
Only suitably qualified personnel should install this equipment.
This passive infrared presence detector is designed to be fitted to a batten-style luminaire.
Installation
1. Remove the M20 knockout from the end cap of the luminaire.
2. Pass the sensor wires through from the outside and insert the threaded end of the sensor into the hole.
3. A polarising plate can be made in order to prevent rotation of the sensor - an example design is given on
page 3 (Fig. 5).
4. If a polarising plate is to be used, pass the wires through the slot and position the polarising plate against
the inside face of the end cap. Ensure that the tab is positioned correctly i.e. at the ceiling side, away from
the lamp.
5. Fit and tighten the locknut.
6. Connect the wires in accordance with the wiring instructions.
SENSOR
ENSURE THAT THE TWO O-RINGS
ARE FITTED AS SHOWN
If there is insufficient space for the locknut,
the adaptor shown below (Fig. 3) can be used.
20mm Female Adaptor
MK part number EFA/2
Fig. 3
Angled Washer Kit (supplied)
If the light fitting has an angled (drafted) end
face then use the kit provided as shown
(Fig. 4).
Fig. 1a
IP65 SENSOR
Fig. 4
MSB1001DALIT - for use with DALI ballasts
OPTIONAL POLARISING PLATE
IP65 LIGHT FITTING
Fig. 2
20mm O-RING LUMINAIRE WITH ANGLED END FACE
ANGLED SPACER
- 2 -
LOCKNUT
Fig. 1
ANGLED WASHER