Advertisement

Quick Links

Installation & Service
LIFT FRONT STRAIGHT GLASS MEAT/SEAFOOD/DELI MERCHANDISERS
This manual has been designed to be used in conjunction with the
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF - 7 2003.
PRINTED IN Specifications subject to REPLACES
IN U.S.A.
Get user manuals:
See SafeManuals.com
TLM, TLF, TLD
Medium Temperature Service Display Cases
General (UL/NSF) Installation & Service Manual.
Save the Instructions in Both Manuals for Future Reference!
change without notice.
EDITION
Manual
ISSUE
11/05
DATE
Tyler Refrigeration * Niles, Michigan 49120
PART
4/07
9037179
NO.
E
REV.

Advertisement

Table of Contents
loading

Summary of Contents for Tyler TLM

  • Page 1 This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF - 7 2003. PRINTED IN Specifications subject to REPLACES ISSUE PART 11/05 4/07 9037179 IN U.S.A. change without notice. EDITION DATE REV. Tyler Refrigeration * Niles, Michigan 49120 Get user manuals: See SafeManuals.com...
  • Page 2: Table Of Contents

    ........22 End Coil Cover (TLM/TLF) ....... . 22 Refrigeration Line Cover (TLM Only) .
  • Page 3 Cladding and Trim Parts List ......34 TYLER Warranty ....(See General-UL/NSF I&S Manual)
  • Page 4 TLM, TLF, TLD SPECIFICATIONS TLD Lift Front Straight Glass Blower Service Merchandisers TLM/TLF Lift Front Straight Glass Gravity Service Merchandisers Page 4 April, 2007 Get user manuals: See SafeManuals.com...
  • Page 5 Installation & Service Manual TLM, TLF, TLD April, 2007 Page 5 Get user manuals: See SafeManuals.com...
  • Page 6 TLM, TLF, TLD Page 6 April, 2007 Get user manuals: See SafeManuals.com...
  • Page 7: Pre-Installation Check List

    Installation & Service Manual TLM, TLF, TLD Pre-Installation Check List INSTALLATION PROCEDURES WARNING WARNING These cases are very heavy and require The raised front glass projects in front of two or more people to unload, move, the case and could cause personal injury position and/or install them.
  • Page 8: Carpentry Procedures

    TLM, TLF, TLD NOTE Carpentry Procedures Front and rear edges of legs or pedestals Case Line-Up should always be used to line-up cases. Cases with legs have built-in leveling Before starting the case line-up, review the adjustment capabilities. Cases with store layout floorplans and survey the areas pedestals use 6”...
  • Page 9: Lift Front Glass Leveling Instructions

    Installation & Service Manual TLM, TLF, TLD Lift Front Glass Leveling Instructions Accurate leveling is critical for the proper operation of the lift glass on this case. In some instances, setting the case on an apparently level floor can cause the lift glass to fit improperly.
  • Page 10: Rear Rail Cover And Close-Off Installation

    TLM, TLF, TLD Rear Rail Cover & Close-off Installation Trim Installation (Cases with Pipe Legs) Position rear rail cover (1) over rear raceway opening and secure with screws in every hole. Bottom and End Close-off Installation Kickplate, optional rear bottom and end close-offs have spring clips on their back sides that secure to the pipe legs.
  • Page 11: Optional 2" Bumper Installation

    One thermostat and one solenoid are with screws, if required, using same required for up to three cases. alignment as old bumper track. The TLM, TLF and TLD cases use an electronic thermostat for improved temperature control. Typical Service Case with Gravity Coil 2.
  • Page 12: Setting The Electronic Thermostat (Tlm/Tld/Tlf)

    TLM, TLF, TLD THERMOSTAT BULB PLACEMENT 2. Connect sensor wires to the common (COM) and sensor (SEN) terminals of the terminal strip located at the top left of the printed circuit board. The sensor leads are interchangeble. 3. Set the Heating/Cooling jumper blocks to Typical Service Case with Blower Coil the “COOL ”...
  • Page 13: Electrical Procedures

    120V circuit. The The wiring diagrams on pages 14 thru 21 will case fan circuit is not cycled on this case. cover all TLM, TLF and TLD case circuits. July, 2005 Page 13 Get user manuals:...
  • Page 14: Tlm/Tlf Case Circuits (4', 6', 8' & 12' Cases)

    TLM/TLF Domestic & Export (50 Hz) Case Circuits (4’,6’, 8’ and 12’ Cases) Page 14 July, 2005 Get user manuals: See SafeManuals.com...
  • Page 15 July, 2005 Page 15 Get user manuals: See SafeManuals.com...
  • Page 16 Page 16 July, 2005 Get user manuals: See SafeManuals.com...
  • Page 17 July, 2005 Page 17 Get user manuals: See SafeManuals.com...
  • Page 18: Tld Case Circuits (4', 6', 8' & 12' Cases)

    TLD Domestic & Export (50 Hz) Case Circuits (4’, 6’, 8’ and 12’ Cases) Page 18 July, 2005 Get user manuals: See SafeManuals.com...
  • Page 19 July, 2005 Page 19 Get user manuals: See SafeManuals.com...
  • Page 20 Page 20 July, 2005 Get user manuals: See SafeManuals.com...
  • Page 21 July, 2005 Page 21 Get user manuals: See SafeManuals.com...
  • Page 22: Cleaning And Sanitation

    Lower Trays and Screens reverse order. 1. Open the front straight glass by lifting Refrigeration Line Cover (TLM Only) the handle at the bottom. 1. Open the front straight glass by lifting the 2. Remove product from the case interior.
  • Page 23: Cleaning Instructions

    Cleaning Instructions WARNING TYLER Refrigeration does not recommend the use of high pressure cleaning equipment on service style cases!! The sealing of front glass and end joints is critical in these cases and high pressure cleaners can penetrate and/or damage these seals. Damaged seals allow water leaks and/or air leaks that can cause poor case refrigeration.
  • Page 24 TLM, TLF, TLD TYPE OF CLEANING CLEANING AGENT* APPLICATION METHOD** EFFECT ON FINISH Paste NuSteel or DuBois Rub with dry cloth. Use a Use in direction of polish lines Temp small amount of cleaner. on No. 4 (polished) finish. May scratch No. 2 (mill) and No.
  • Page 25: General Information

    Installation & Service Manual TLM, TLF, TLD Grease and oil Organic solvents such as Rub with a cloth. Organic Satisfactory for use on all carbon tetrachloride, tri- solvents may be flammable finishes. chlorethylene, acetone, kero- and/or toxic. Observe all sene, gasoline, benzene, precautions against fire.
  • Page 26: Mezzanine Shelving

    One level of shelving is optionally The optional scale shelf is mounted to the available for TLM and TLF cases, while two mullion on the back of the case. The shelf levels of shelving is available for TLD cases.
  • Page 27: Service Instructions

    Installation & Service Manual TLM, TLF, TLD SERVICE INSTRUCTIONS Light Servicing See “General (UL/NSF) I&S Manual” for Connecting the Refrigeration preventive maintenance, T-8 lamp, fan Piping and Components blade and fan motor (TLD) replacement instructions replacement. WARNING Ballast and Lighting Locations...
  • Page 28: Light Shield Anti-Sweat Replacement

    Front Glass Anti-Fogging System Replacement Service WARNING TLM, TLD and TLF cases have a front glass Shut off or disconnect power supply to anti-fogging fan and a front glass anti-sweat case before replacing the light shield heater. Use the following instructions to anti-sweat.
  • Page 29: Front Glass Anti-Fog Fan Replacement

    Installation & Service Manual TLM, TLF, TLD 6. Note position of old heater wire and foil Lift-Glass Replacement tape. Unpug heater wire from harness WARNING connector and remove foil tape and heater wire. Install new heater wire and Wear safety glasses and gloves and use foil tape in same position as removed.
  • Page 30: Lift-Glass Gas Piston Replacement

    TLM, TLF, TLD NOTE Lift-Glass Gas Piston Replacement Note positioning and installation of top WARNING edge channel before removing. The TL series cases rely upon gas pistons to assist lifting the glass and holding it in the raised position. The glass is heavy and difficult for one person to lift alone while replacing a gas piston.
  • Page 31: Color Band, Bumper And Bumper Retainer Replacement

    Installation & Service Manual TLM, TLF, TLD Color Band, Bumper and Bumper Retainer Replacement NOTE Color band, bumper and bumper retainer must be removed to access the upper screws in the front upper cladding. 1. Open the lift glass and remove screws, color band and color band backers from bottom glass support.
  • Page 32: Anti-Sweat Heater Wire Deflector Kit Replacement (Tld)

    TLM, TLF, TLD Anti-Sweat Heater Wire Deflector Kit Replacement (TLD Only) All TLD models have anti-sweat heaters under each lower rear door frame. Use the following instructions to replace an anti-sweat heater wire deflector kit. WARNING Shut off or disconnect power supply to case before replacing any part of the anti-sweat heater wire deflector kit.
  • Page 33: Parts Information

    5191445 5191445 5191445 5191445 Electronic Thermostat 9043552 9043552 9043552 9043552 Check Valve (TLM) 5199417 5199417 5199417 5199417 For information on operational parts not listed above contact the TYLER Service Parts Department. November, 2005 Page 33 Get user manuals: See SafeManuals.com...
  • Page 34: Cladding And Trim Parts List

    TLM, TLF, TLD Cladding and Trim Parts List Item Description 4’ 6’ 8’ 12’ Rear Top Cladding, BRT/SS 9808686 9802641 9802642 9802643 Color Band, Ptd. 9808701 9802209 9800737 9801600 Color Band Joint Trim, Ptd. 9801776 9801776 9801776 9801776 Bumper Retainer, Std.
  • Page 35 Installation & Service Manual TLM, TLF, TLD Item Description 4’ 6’ 8’ 12’ Raceway Cover, Ptd. 9801263 9802224 9801263(2) 9801263(3) Screw 9043080(5) 9043080(5) 9043080(10) 9043080(15) Lwr. Rear Joint Trim, Ptd. 9801802 9801802 9801802 9801802 Screw 9024814(4) 9024814(4) 9024814(4) 9024814(4) Opt.Lwr. Rr. Joint Trim, BRT SST 9802645...

This manual is also suitable for:

TlfTld

Table of Contents