Advanced ultrasonic vinyl record cleaner (32 pages)
Summary of Contents for HumminGuru S-DUO HG02
Page 1
Digital Pressure Gauge for Turntable Stylus Owner’s Manual Model: HG02 Thank you for buying the HumminGuru S-DUO. To apply this product safely and properly, please read the manual thoroughly and well understand before use. After reading, please keep the manual handy.
The HumminGuru S-DUO executes two main functions: ultrasonic cleaning and vertical Indicates prohibition (must Indicates mandatory (must do). down force measurement. The device is limited to serve for turntable stylus only and not do). The details of the The details of the mandatory applicable to moving magnet and the moving coil cartridge.
Page 3
• DO secure the battery compartment. • DO NOT disassemble, fix, repair, or modify the device in any way without authorization of the manufacturer. • DO NOT mix old and new batteries, or mix different types or makes of batteries. This can cause leakage or rupture, resulting in personal •...
Overview Controls and Functions Bi-Directional LCD Display On/Off Touch Control Scale Platform Stylus Rubber Support x 3 • To power on the device, touch the “ ” icon once. Water Basin • To power off the device, touch the “ ”...
Page 5
On/Off Touch Control Water Basin Ultrasonic Cleaning Mode Must insert the rubber support properly onto the water basin, and then use the water dropper to The ultrasonic cleaning ( ) is a default mode. The cleaning process takes 20 fill up the basin with water before starting the seconds per cycle and the countdown timer on the screen indicates the number of ultrasonic cleaning mode.
Page 6
Battery Installation/Replacement Simply touch the pressure gauge mode ( ) once to reset zero. The HumminGuru S-DUO is supplied with four 1.5V Type AAA (LR 03) batteries. For best performance, we recommend Duracell® Alkaline batteries. The Lid Open the battery compartment...
Setting up the Device Using Ultrasonic Cleaning Open the lid. Install 4 new AAA batteries Select one of the stylus rubber support that suits for your cartridge and place it onto the water basin. Notice: Go to page 8 for instruction Place on the turntable platter and Select the function mode to start.
Page 8
Using Pressure Gauge Rest the cartridge on top of the rubber support and ensure the stylus tip is submerged in the water. Flip the device 180 degree if the user switches to the pressure gauge mode after ultrasonic cleaning. Place the stylus cartridge on top of Touch the ( ) to start the pressure the scale platform.
Errors and Trouble Shooting Maintenance Clean the water basin and wipe away excess Release excess water When the pressure gauge is overloaded ≥10g, three dashes water with a cotton swab or a damp cloth from the dropper and the symbol will appear on the display. after use.
LIMITATION ON DAMAGES: Pursuant to this Limited Warranty, HumminGuru will, at its option, (i) repair the product HUMMINGURU SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL...
Need help?
Do you have a question about the S-DUO HG02 and is the answer not in the manual?
Questions and answers