READ AND SAVE THESE INSTRUCTIONS
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
1. Read your owner's manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service
panel disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a warning
device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan.
Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring,
and do not operate fan without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical
Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution
against possible electrical shock. Electrical installation should be made or approved
by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting
at least 50 pounds. Use only U.L. outlet boxes listed as "Acceptable for Fan Support",
and use the mounting screws provided with the outlet box. Most outlet boxes com-
monly used for support of light fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan
blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent
accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling
fan. If you do not know enough about electrical wiring, have your fan installed by a
licensed electrician.
WARNING: To avoid fire, shock, or injury, do not use an Emerson or any other brand of
control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product
and/or any accessories designated specifically for use with this product by Emerson
Electric Co. Substitution of parts or accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when
installing the blade flanges, balancing the blades or cleaning the fan. Do not insert for-
eign objects in between rotating fan blades.
Part No. F40BP72860001
Page 1
CFDC
Downrod Coupler
(For Emerson Ceiling Fans with
Unthreaded Downrods)
WARNING
!
Safety Instructions
Series
Form No. BP7286-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFDC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson CFDC Series

  • Page 1 If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. WARNING: To avoid fire, shock, or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
  • Page 2: Tools Needed For Assembly

    If you do not know enough about electrical wiring, have your fan installed by a licensed electrician. WARNING: To avoid fire, shock, or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
  • Page 3 1. Using the setscrew wrench (supplied), motor your fan has. There are two types of install the four setscrews into the cou- motors used on Emerson fans: the K55 pler body as shown (Figure 4). Be sure motor and the 188mm or 153mm motor.
  • Page 4 CFDC Coupler 6/4/05 1:19 AM Page 4 6. The four coupler setscrews can now be 10. Position the ends of the new wire tightened. Using the supplied setscrew leads 6” above the hanger ball. Strip wench, carefully turn each setscrew - 3/8”...
  • Page 5 CFDC Coupler 6/4/05 1:19 AM Page 5 motor coupling. Align the cross holes in Assembly Procedure for Fans downrod with cross holes in motor with 153mm or 188mm Motors coupling. Insert clevis pin through the (To simplify final fan installation, do not cross holes carefully, to avoid damag- install the fan blades and flanges to the ing the electrical wires.
  • Page 6 CFDC Coupler 6/4/05 1:19 AM Page 6 4. Cut the black, blue and white wires 7. Insert the hairpin clip into the hole in 3” from the connector. Strip 3/8” of the end of the clevis pin (Figure 13). Be insulation from the end of each wire sure the hairpin is securely in place.
  • Page 7: Repair Parts

    Follow the Owner’s Manual supplied with the ceiling fan to complete the installation of the fan assembly into the ceiling mounting bracket. Repair Parts Ref. Description Model CFDC Series Parts Bag Containing: 762743 One 5/32” Setscrew Wrench — Two 1/4” x 1” Shoulder Screws, #10-24 UNC Thread —...
  • Page 8: Limited Warranty

    What Will Emerson Electric Company Do To Correct Problems: Emerson Electric Company will replace a defective Emerson downrod coupler at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE...

Table of Contents