Specifications:
Detection method
Optical
Power Supply
Built-in DC3V Lithium battery (battery not replaceable)
Battery Lifetime
10 years
Monitored area
40 m²
Operating temperature
0 °C - 45 °C
Operating Humidity
< 93 %
Date of replacement
See product label
Individual alarm indicator
Yes
Silence feature (hush mode)
Yes | Hush time: 10±1 minutes
Low battery warning
Yes
Low battery silence facility
Yes | Hush time: 10 hours
installation in leisure
Caravan and Motor Home Suitability No
Mounting Location
Ceiling or wall
Inter-connectable
Yes | max. 40 devices
Wireless frequency
433.42MHz
Wireless distance
Max. 100 metres in free field
ISO 8201 BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s -
Local smoke alarm sound pattern:
pause 1.5s, with the red LED flash, repeat this alarm pattern.
Beep Beep - pause 1s, with the red LED flash, repeat this alarm
Wireless alarm sound pattern
pattern.
Product function description:
Function
Visual Indication
The Red LED flashes every 40
Normal Alarm Function
seconds.
Test (Button Pressed On Direct Unit)
• Test by pressing the TEST button on the smoke alarm
Flashes once per second for 3
at least 5 seconds.
seconds, pauses for 1.5 seconds
• The alarm will sound if all electronic circuitry, horn
then cycles again.
and battery are working properly. If no alarm sounds,
refer to "Trouble Shooting".
Test (Wireless Paired Unit)
Flash twice every 1 second for
duration of 5 minutes.
Alarm being tested signals others in the network
Flashes once per second for 3
Local Alarm Detected Smoke
seconds, pauses for 1.5 seconds
then cycles again.
Paired Wireless Alarm
None
Silence Feature (Hush Mode)
• This smoke alarm has a built-in Silence feature.
• If cooking or other non-hazardous sources cause
The Red LED flashes every 8
the alarm to sound, it can be temporarily silenced by
seconds.
pressing the HUSH button for above 2 seconds.
• The alarm enters silence mode for 10 minutes. After
the 10 minute dormant period, the smoke alarm will
resume normal operation.
Low Battery Warning
The Red LED flashes every 40
Need to replace for a new smoke alarm
seconds.
Connected Low Battery Warning
1 flash every 3 hours.
(Connected device battery is running low)
Low Battery Warning Silence Feature
None
(Low battery warning is muted)
Internal Fault Warning
None
Need to replace smoke alarm
Caution:
•
Before using the silence function, identify the source of the smoke and ensure conditions are safe. The unit will resume
normal operation after 10 minute silence.
•
DO not use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and result in a fire.
•
Pull out the yellow tag insulation sheet in battery compartment before installing smoke alarm, or the smoke alarm won't
work properly.
If the alarm sounds, and it is not being tested, it means the unit detected smoke. THE SOUND OF THE ALARM REQUIRES
•
YOUR IMMEDIATE ATTENTION AND ACTION.
Audio Indication
None
Siren once per second for 3 seconds
then pause 1.5 seconds then cycle
again.
Beep twice for 10 seconds.
Siren once per second for 3 seconds
then pause 1.5 seconds then cycle
again.
Continuous 2 beeps every 2 seconds.
None
Beep every 40 seconds.
1 beep every 3 hours.
None
Beep every 40 seconds.