Serial Number
160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATH2G18 and is the answer not in the manual?

Questions and answers

Summary of Contents for AR ATH2G18

  • Page 1 Operating and Service Manual ATH2G18 Model 10029201 Part Number Serial Number 160 School House Road, Souderton, PA 18964 • 215-723-8181 • Fax 866-859-0582 • www.arworld.us...
  • Page 3 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006 concerning the Registration, Evaluation, Authorization and Restriction of Substances of Very High Concern Chemicals (SVHC) Supporting documentation is held by AR RF/Microwave Instrumentation’s Quality department in Pennsylvania, United States. Place of issue:...
  • Page 5 The caution symbol denotes a potential hazard. Attention must be given to the statement to prevent Your AR equipment may have more than one power supply cable. Use damage, destruction, or harm. only approved power cable(s). If you have not been provided with a Dangerous voltages are present.
  • Page 6 EQUIPMENT CONTAINING LASERS risk of serious injury due to unsafe AR Field Probes (FL/PL Series) and Field Analyzers (FA product handling should be a fundamental Series) are Class 1 laser products containing embedded consideration every user.
  • Page 7 Zur Vermeidung von Personen- oder Sachschäden gilt BEVOR SIE DAS GERÄT ANSCHLIESSEN es, die Hinweise zu beachten. Ihre AR-Ausrüstung hat möglicherweise mehr als ein Stromversorgungskabel. Gefährliche elektrische Spannungen sind vorhanden. Verwenden Sie nur zugelassene Stromkabel. Falls Sie kein Stromkabel oder Höchste Vorsicht ist geboten.
  • Page 8 Die meisten Geräte müssen während des Versands, der Montage und des Gebrauchs LASER-INFORMATION transportiert werden. Jeder Nutzer sollte sich AR - Feldsonden (FL/PL-Serie) und Feldanalysatoren (FA-Serie) über das Risiko von schweren Verletzungen sind Laserprodukte der Klasse 1 mit eingebetteten Klasse-4- durch unsachgemäße...
  • Page 9 électrode de mise à la Votre équipement AR peut disposer de plus d’un câble d’alimentation terre de protection. électrique. Utilisez uniquement un ou des câbles d’alimentation approuves.
  • Page 10 éliminer le risque injustifié de blessures causées par le levage est fournie par les méthodes de travail de NIOSH (publication Les sondes de champ AR (série FL/PL) et les analyseurs de n° 94-110) disponibles sur : champ (série FA) sont des produits laser de classe 1 contenant des lasers intégrés de classe 4.
  • Page 11 Er zijn gevaarlijke elektrische spanningen aanwezig. Wees uiterst voorzichtig. VOOR HET OPZETTEN VAN DE STROOM Uw AR-apparatuur kan meer dan een netvoedingskabel bezitten. Gebruik alleen goedgekeurde netvoedingskabel(s). Koopt een Wijst op een terminal aan die bedoeld is voor aansluiting netvoedingskabel die is goedgekeurd voor gebruik in uw land als u...
  • Page 12 APPARAAT DAT LASERS BEVAT distributie, de assemblage en het gebruik moeten worden behandeld, moet het risico AR-terreinsondes (FL/PL-serie) en terreinanalysatoren (FA- op ernstig letsel als gevolg van een serie) zijn laserproducten van klasse 1 met ingesloten onveilige behandeling van het product een klasse 4-lasers.
  • Page 13: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS ....................i GENERAL INFORMATION ................1 General Description ................... 1 Specifications ....................1 Installation ......................1 1.3.1 Connections ....................... 1 1.3.2 Power Amplifier Selection ................. 1 1.3.3 General Caution Notes ..................2 TYPICAL CURVES ..................7 VSWR .......................
  • Page 14 Model ATH2G18...
  • Page 15: General Information

    2–18GHz. The Model ATH2G18 has a power-handling capability of 50 watts (W) with a minimum gain of 6dB at 2GHz, increasing linearly to more than 11dB at 18GHz.
  • Page 16: General Caution Notes

    1.3.3 General Caution Notes CAUTION: The Model ATH2G18 is capable of generating output voltages that are dangerous to human life and can cause serious microwave burns to human tissue. Therefore, never stand or walk in front of the antenna when it is radiating microwave energy.
  • Page 17 Antenna 2GHz–18GHz The Model ATH2G18 is a wide band, high gain, high power microwave horn antenna. With a minimum gain of 6dB over isotropic, the Model ATH2G18 supplies the high intensity fields necessary for RFI/EMI field testing within and beyond the confines of a shielded room. The Model ATH2G18 is extremely compact and lightweight for ready mobility, yet is built tough enough for the extra demands of outdoor use and easily mounts on the rear flange.
  • Page 18 ATH2G18 Input Power Frequency (GHz) ATH2G18 Gain ATH2G18 3dB Beamwidth H‐Plane (Degrees) E‐Plane (Degrees) Frequency (GHz) Frequency (GHz) Page 2 of 3...
  • Page 19 ATH2G18 Field Strength Calculated at 1 Meter 1000 20 Watts 15 Watts 10 Watts 5 Watts 100 Watts 3 Watts 2 Watts 50 Watts 1 Watts 0.5 Watts Frequency (GHz) ATH2G18 Field Strength Calculated at 3 Meters 20 Watts 15 Watts 10 Watts 5 Watts 100 Watts 3 Watts 50 Watts 2 Watts 1 Watts 0.5 Watts...
  • Page 21: Typical Curves

    Typical VSWR Freq GHz GAIN VS. FREQUENCY AND BEAMWIDTH VS. FREQUENCY These representations are shown on the AR data sheet preceding this section. 2.4. TYPICAL CURVES, E-PLANE AND H-PLANE These curves are shown on the pages that follow. Rev B...
  • Page 22: E-Plane, 2 Ghz

    Model ATH2G18 2.4.1 E-PLANE, 2 GHz 2.4.2 H-PLANE, 2 GHz Rev B...
  • Page 23: E-Plane, 4 Ghz

    Model ATH2G18 2.4.3 E-PLANE, 4 GHz 2.4.4 H-PLANE, 4 GHz Rev B...
  • Page 24: E-Plane, 6 Ghz

    Model ATH2G18 2.4.5 E-PLANE, 6 GHz 2.4.6 H-PLANE, 6 GHz Rev B...
  • Page 25: E-Plane, 8 Ghz

    Model ATH2G18 2.4.7 E-PLANE, 8 GHz 2.4.8 H-PLANE, 8 GHz Rev B...
  • Page 26: E-Plane, 10 Ghz

    Model ATH2G18 2.4.9 E-PLANE, 10 GHz 2.4.10 H-PLANE, 10 GHz Rev B...
  • Page 27: E-Plane, 12 Ghz

    Model ATH2G18 2.4.11 E-PLANE, 12 GHz 2.4.12 H-PLANE, 12 GHz Rev B...
  • Page 28: E-Plane, 14 Ghz

    Model ATH2G18 2.4.13 E-PLANE, 14 GHz 2.4.14 H-PLANE, 14 GHz Rev B...
  • Page 29: E-Plane, 16 Ghz

    Model ATH2G18 2.4.15 E-PLANE, 16 GHz 2.4.16 H-PLANE, 16 GHz Rev B...
  • Page 30: E-Plane, 18 Ghz

    Model ATH2G18 2.4.17 E-PLANE, 18 GHz 2.4.18 H-PLANE, 18 GHz Rev B...
  • Page 31: Outline Drawing

    3. OUTLINE DRAWING An outline drawing (Drawing Number 10029204) of the Model ATH2G18 Microwave Horn Antenna is shown below. NOTE: All dimensions shown are typical. Rev B...
  • Page 32 Model ATH2G18 Rev B...
  • Page 33: Polarization Of Horn Antennas

    4. POLARIZATION OF HORN ANTENNAS Rev B...
  • Page 34 Model ATH2G18 Rev B...
  • Page 35 These modules are not field-repairable and should never be opened outside of AR’s Microelectronics Lab. The modules in these product lines have a security label on two sides of the modules between the housing and lid/cover. If the security label is removed and or cut, the warranty of the module will be voided.