MAINTENANCE
1.11 Removing Solenoid Valve Coil (SVA)
(1) Remove the service cover.
(2) Disconnect the connector on the outdoor unit PCB.
(3) Remove one securing screw for solenoid valve coil (SVA) and slide the solenoid valve coil (SVA) upward.
(4) To install a new solenoid valve coil, reverse the removal procedure.
Tool
Phillips Screwdriver
Model: 3~3.5HP
Model: 4~6.5HP
Model: 7~12HP
137