PAC 212 Install Manual page 17

Table of Contents

Advertisement

9
One Touch™ Test Mode
To speed up installation and testing, One-Touch™ testing is provided which allows the controller functionality to be tested at the
controller or reader.
Test
Action
Normal
Operation
Hold down One-Touch™
button for less than 2
seconds. Present keys, press
One-
RTE switches and observe
Touch™
LEDs.
View Mode
Automatically exits after 2
minutes.
One-
Touch™
Hold down One-Touch™
Active
button for 2 to 4 seconds.
Mode
Present a key to each reader
(the lock will activate).
Reader and
Press the Request to Exit
Request to
switch (the lock will activate).
Exit Test
Open the door contact.
Present a key to a reader, press the Request to Exit
switch and open the door contact simultaneously.
Auxiliary
Remove link to 0V on tamper or open circuit tamper
and Lock
switch.
Relays Test
Remove link to 0V on emergency override or leave
open circuit tamper switch.
Remove the link between TAMP and 0V on the Tamper
Tamper and
& Override terminal block.
Override
Remove the link between OVRD and 0V on the Tamper
Test
& Override terminal block.
Hold down One-Touch™
Leave One-
button for less than 2
Touch™
seconds. One-Touch™ Test
Active Test
mode will automatically be
mode
timed out after 1 hour,
power up or power down.
PAC 212 Access Controller Install Guide
Observation
Controller
Green
Green-Red-Yellow
Green
Green-Red-Yellow
Green-Red-Yellow
Green-Red-Yellow
Green-Red-Yellow
Green
Green-Red-Yellow
Green-Red-Yellow
Green-Red-Yellow
Green
GREEN flashes at
normal rate.
All LEDs off.
GREEN flashes at
normal rate.
GREEN on, valid key
presented to reader.
GREEN flashes, invalid
key presented to
reader.
RED on, door open.
YELLOW on, RTE
switch has been
pressed.
GREEN flashes faster
than normal.
GREEN flashes once for
SIGA, twice for SIGB.
GREEN flashes three
times and YELLOW is
on.
GREEN flashes four
times and RED is on.
The appropriate auxiliary relay is activated.
Both auxiliary relays are activated.
The auxiliary relay is activated.
The auxiliary relay is activated but the door relays are
unaffected.
Both auxiliary and lock relays are activated, the door opens
and the lock operates.
System status: GREEN
flashes at normal rate
again.
- 17 -
Reader
Normal operation of
the reader.
Red
Normal operation of
the reader LED
changes, e.g. if default
Green
is red it changes to
green.
Reader LED flashes
once for SIGA, twice
Red
for SIGB.
Reader LED flashes
three times.
Red
Reader LED flashes
four times.
Red
Reader LED returns to
normal operation.
Red