NEFF S189YCX02E Information For Use page 47

Hide thumbs Also See for S189YCX02E:
Table of Contents

Advertisement

Fault
E:3200 or indicator
for water supply lights
up.
E:6102 lights up.
E:6103 lights up. Wa-
ter is not drained.
Cause and troubleshooting
Remove the filter from the supply hose
5.
Clean the filter.
6.
Re-insert the filter in the supply hose.
7.
Screw the water connection back on.
8.
Check the water connection for leaks.
9.
Restore the power supply.
10.
Switch the appliance on.
11.
Not an appliance fault. Wastewater pump is blocked
or the cover of the wastewater pump is loose.
Clean the wastewater pump.
1.
→ "Clean wastewater pump", Page 52
Secure the cover of the wastewater pump so it
2.
clicks into position.
→ "Clean wastewater pump", Page 52
Not an appliance fault. Siphon connection is still
closed or the wastewater hose is kinked or blocked.
Check the connection to the siphon and open if ne-
1.
cessary.
Install wastewater hose without kinks.
2.
Remove residues.
3.
Troubleshooting en