Download Print this page
T&D TR-52i Introductory Manual

T&D TR-52i Introductory Manual

Thermo recorder

Advertisement

Quick Links

Introductory Manual
Thank you for purchasing this product.
Carefully read and fully understand these instructions before
using this unit.
Shimadachi 817-1, Matsumoto, Nagano 390-0852 Japan
Tel:+81-263-40-0131 Fax:+81-263-40-3152
Homepage:http://www.tandd.com/ E-mail:support@tandd.com
Copyright T&D Corporation. All rights reserved. 2010.09 16504710002 (1st Edition)
This is printed using recycled paper.
TR-51i
Internal Temperature Sensor Type
Immersion proof
Package Contents:
Data Logger and Common Accessories for
TR-51i and TR-52i
TR-52i
External Temperature Sensor Type
Splash proof
Package Contents:
Data Logger, Temperature Sensor TR-5106, and Common
Accessories for TR-51i and TR-52i.
Common Accessories for TR-51i and TR-52i:
Lithium Battery LS14250 with Tube/Strap/Introductory Manual (including Warranty)
Appearance Diagram and Part Names
Infrared Port
ALM
(Warning LED)
Optical
Communication Area
Sensor
Jack
Thermo Recorder TR-51i/52i will be referred to as the "Unit" in this manual.
Installing the Battery
Recording will start after the battery is inserted.
1.
Remove the screws and open the cover.
Screws
Make sure to use the proper size and type of
screwdriver.(Phillips head #1 screwdriver)
2.
Insert the attached Battery.
Do not remove the battery from its tube casing.
Cover
-If using a CR2 lithium battery, the tube is not
necessary.
Rubber Packing
3.
Check the rubber packing condition and close
the cover in the same manner as when you
opened it.
-If dirt or scratches are present on the rubber
packing, water resistance will be reduced.
Please remove the dirt or replace the rubber
packing if there're any cuts or scratches.
  Attached Battery
-
Be sure to completely close the cover.
(with tube)
-
Make sure not to over tighten the screws.
(Appropriate torque: 20N/cm 〜 30N/cm〔2Kgf/cm 〜 3Kgf/cm〕 )
Specifications
Device Name
TR-51i
TR-52i
Measurement Item
Temperature
Temperature
Number of Channels
1 Ch (Internal Sensor Type)
1 Ch (External Sensor Type)
Measurement Range
- 40 to 80℃
- 60 to 155℃
Response Time (in 90% still air)
About 35 minutes
 -
Measuring Accuracy
Avg. ± 0.5℃
Avg. ± 0.3℃ :- 20 to 80℃
Avg. ± 0.5℃ :- 40 to - 20℃
Avg. ± 1.0℃ :- 60 to - 40℃
      
Measurement Display Resolution
0.1℃
Recording Intervals
Select from 15 choices:1, 2, 5, 10, 15, 20 and 30 seconds / 1, 2, 5,
10, 15, 20, 30 and 60 minutes
Storage Capacity
Up to 16,000 readings
Recording Start Method
Immediate Start / Programmed Start
Recording Modes
Endless / One Time
LCD Displayed Items
Measured Temperature, Recording Status, Recording Mode
Infrared Communication Status
Battery Life Warning, Unit of Measurement, Full (Storage Capacity
FULL), Unconnected Sensor
Measurement Range Exceeded, Upper/Lower Limit Exceeded
Communication Interfaces
Optical / Infrared Communication
Infrared Communication
IrPHY 1.2 low power
Communication Time
When downloading a Unit at full storage capacity:
 Optical Communication : about 25 seconds (TR-50U) / about
150 seconds (other devices)
 Infrared Communication: about 55 seconds (TR-57DCi)
Power(*1 )
Lithium Battery (LS14250)/ Lithium Battery (CR2)
Battery Life(*2 )
About 4 years ( 2 years if it's been selected to "Permit" infrared
communication)
Waterproof Capacity
Immersion proof
Splash proof
Dimensions
H62 × W47 × D19mm(excluding protrusions and sensor part)
Weight
About 54g (including battery)
About 55g (including battery /
excluding sensor)
Operating Environment
- 40 to 80℃
When using Lithium Batteries (CR2) sold in stores : -20 to 60℃
Data Collection Devices
Communication Ports:TR-50U / TR-50C
Data Collectors: TR-57DCi / TR-57U / RTR-57U / RTR-57C
(*1) The included Lithium Battery (LS14250) is not sold in stores. Please purchase the "Optional Battery
Set TR-11P2" for replacement.
(*2) Battery life varies depending upon measuring environment, frequency of communication, Unit
settings, and battery performance.
Temperature Sensor TR-5106
Sensor Temperature Durability
- 70 to 180℃
Thermal Time Constant
In air: about 15 sec. / In water: about 2 sec. 
Temperature Sensor TR-5106 (Supplied with TR-52i)
600
Waterproof
[unit: millimeters]
Make sure that the sensor is completely
inserted until you hear a "click" sound.
① Thermistor ② Fluoropolymer Coated Electrical Wire
③ Specialized Connector
The TR-52i only becomes splash proof
when the sensor has been connected.
Notes about Battery Installation
- After inserting the battery, it may occur that nothing appears in
the display for about 10 seconds; this is not a malfunction.
- If a new battery has been installed and nothing appears in the
display, please remove and re-insert the battery.
-When inserting a battery, make sure no water or foreign
objects get inside the case.
- Make sure that + and – are in the correct direction.
About Lithium Batteries: LS14250 and CR2
-
Operating temperature range will vary depending on the battery.
If you are using in an environment below -20℃ , above 60℃ , or
in a situation such as transportation where continued vibration is
likely to occur, we suggest the use of the lithium battery LS14250.
-
The lithium battery LS14250 is not sold in stores; please
purchase the "Optional Battery Set TR-11P2" for replacement.
-
Please store the LS14250 in a place that is 20℃ or less.
-
When changing a CR2 battery, we strongly suggest changing
the rubber packing and the drying agent. In this case, please
purchase the "Optional Maintenance Set TR-00P1".
Notices about this Introductory Manual
In order to properly use this product, please carefully read this manual before using.
T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or
malfunction as falling outside the conditions for free repair outlined in the attached warranty.
- All rights of this Introductory Manual belong to T&D Corporation.It is prohibited to use, duplicate and/or arrange a part or whole of the manual without the permission of T&D Corporation.
- All registered trademarks, company names, product names and logos mentioned herein or for products being used are the property of T&D Corporation or of their respective owners. TANDD ,
"T&D", and the logo of T&D Corporation are all registered property of T&D Corporation.
- Specifications, design and other contents outlined in the manual are subject to change without notice due to continual improvements.
- Please follow the safety precautions outlined in the manual carefully. We cannot guarantee nor are we responsible for safety if this product is used in any manner other than was intended.
80 to 110℃
- On-screen messages in this manual may vary slightly from the actual messages.
- Please notify the distributor from which you purchased this product or T&D Corporation of any mistakes, errors or unclear explanations in this manual.T&D Corporation accepts no responsibility for any
110 to 155℃
damage or loss of income caused by the use of our product.
- This product has been designed for private or industrial use only.It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment, whether
directly or indirectly.
- We are not responsible for any malfunction or trouble caused by the use of our product or for any problem caused by the use of measurement results of our product. Please be fully aware of this before
using our product.
- This Introductory Manual cannot be reissued, so please keep it in a safe place.
- Please read the warranty and provisions for free repair carefully.
Safety Precautions and Instructions
The following items should be strictly obeyed for the safe usage of this product, and for protecting yourself and other people from bodily harm and/or damage to property.
To ensure the proper use of this product, we ask that before using it you carefully read, understand and follow the safety rules and precautions as outlined below.
DANGER
Do not take apart, repair or modify the Unit.
It may result in malfunction or unexpected accidents.
Do not use any batteries other than those specified in this Introductory
Manual.
Doing so may cause fire or malfunction.
If water or a foreign object enters into the Unit, immediately remove the battery
and stop using.
It may result in malfunction or unexpected accidents.
Store the Unit and accessories out of the reach of children. Touching them
may result in unexpected accidents.
Touching them may result in unexpected accidents.
If any smoke, strange smells or sounds are emitted from the Unit, immediately
remove the battery and stop using.
Continued use may cause fire or electrocution.
Please be careful not to touch the Unit during or after use in overly hot or cold
environments; it may cause burns or frostbite.
CAUTION
We are not responsible for any damage, malfunction or trouble, whether direct
or indirect, caused by the use of the Unit.Please be fully aware of this before
using our product.
This Unit has been designed for private and/or industrial use only.It is not for
use in situations where strict precautions are necessary such as in
connection with medical equipment, where directly or indirectly.
Battery life varies depending upon measuring environment, frequency of
communication, Unit settings, and battery performance.
The TR-52i becomes waterproof (splash proof) only after the temperature
sensor has been connected.
Without the sensor connected, neither the sensor jack of the Unit nor the connector part of the
temperature sensor is waterproof; make sure not to get wet.
Contact with oil may cause cracks to appear in the casing of the Unit.When
using the Unit in such an environment, protect the Unit by placing it inside a
polyethylene bag.
FCC Compliance Statement for American Users
This device complies with Part 15 of the FCC Rules.
Operation is subject to following two conditions: (1) this device may not cause harmful
interference. and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE
This equipment has been tested and found to comply with the limits
for a Class A Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
WARNING
This equipment has been verified to comply with the limits for a Class A personal digital device, pursuant
to Subpart B of Part 15 of FCC Rules. Only peripherals (computer input/output devices, terminals,
printers, etc.) certified or verified to comply with the Class A or B limits may be attached to this equipment.
Operation with non-certified or non-verified personal computer and/or peripherals is likely to result in
interference to radio and TV reception. The connection of a non-shielded equipment interface cable to
this equipment will invalidate the FCC Certification of this device and may cause interference levels which
exceed the limits established by the FCC for this equipment.
You are cautioned that changes or modi.cations not expressly approved by party responsible for
compliance could void your authority to operate the equipment.
Do not use or store the Unit in such places as listed below; it may cause
electrocution, fire or damage to the Unit or to your computer.
-Areas exposed to direct sunlight
-Areas exposed in water or high-pressure water flow
-Areas exposed to organic solvents and corrosive gas
-Areas exposed to strong magnetic fields
-Areas exposed to static electricity.
-Areas near fire or exposed to excessive heat
-Areas exposed to excessive dust and smoke
Do not put fingers or foreign objects into the sensor jack.
Do not drop or expose the Unit to a strong impact.
It may cause damage.
Cautions about the Temperature Sensor
When using the included Sensor TR-5106, please take note of the following:
Do not bend the sensor (tip section) or expose it to a strong impact.
This may cause trouble or break the wire.
If the fluoropolymer-coated section of the sensor and/or the cable has a
defect or tear, the waterproof capacity will be lost.
Inspect it before operation.
Insert the sensor tip to about 5cm or more to obtain on accurate temperature
measurement.
Only use the sensor within the sensor temperature durability range.
Distributed by MicroDAQ.com, Ltd.
www.MicroDAQ.com
(603) 746-5524

Advertisement

loading

Summary of Contents for T&D TR-52i

  • Page 1 Appearance Diagram and Part Names Temperature Sensor TR-5106 (Supplied with TR-52i) The TR-52i becomes waterproof (splash proof) only after the temperature sensor has been connected. Without the sensor connected, neither the sensor jack of the Unit nor the connector part of the temperature sensor is waterproof;...
  • Page 2 Time” and the Unit reaches its storage capacity of The latest version of “T&D Recorder for Windows” can be downloaded free of charge from our Web Site. (TR-51i and TR-52i can be operated with the Software 16,000 readings, recording will automatically stop version 1.80E or later.)

This manual is also suitable for:

Tr-51i