PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT:
SAFETY WARNING:
IMPORTANT SAFETY INSTRUCTIONS
CAUTION - TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
1. Use this unit only in the manner
intended by the manufacturer. If you
have any questions, contact
Lynx Grills, Inc. (888) 289-5969
2. Before servicing or cleaning the unit,
switch power off at service panel and
lock the service disconnecting means to
prevent power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
attach a tag to the service panel to
indicate power has been switched off
for maintenance.
3. Install this Rangehood Only with
Remote Blower Models Rated
Maximum 12.8A or Integral Blowers
Models LOHI and LOHE.
C A U T I O N :
F O R
G E N E R A L
VENTILATION USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS OR VAPOR.
NorthlineExpress.com
Save these instructions for the Local Electrical Inspector's use.
INSTALLER:
Please leave these instructions with this unit for the owner.
OWNER:
Please retain these instructions for future reference.
Turn off power circuit at the service panel and lock out panel,
before wiring this unit.
CAUTION - TO REDUCE THE RISK
OF FIRE:
1. Never leave grill unattended.
2. Always turn hood ON when cooking.
3. Clean ventilating fans frequently.
Grease should not be allowed to
accumulate on fan or filter.
CAUTION - TO REDUCE THE RISK
OF INJURY TO PERSONS, IN THE
EVENT GREASE FIRE, OBSERVE
THE FOLLOWING:
1.
BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately.
EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. DO NOT USE WATER, including wet
dish-cloths or towels - a violent steam
explosion will result.
http://www.northlineexpress.com
Installation Instructions
Wall Hoods
Outdoor Applications
Use an extinguisher ONLY if:
3.
a.You know you have a class ABC
extinguisher, and you already know
how to operate it.
b.
the area where it started.
c.
d.You can fight the fire with your back
to an exit.
e fire is small and contained in
e fire department is being called.
Toll-Free 1-866-667-8454
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LOH1836 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lynx LOH1836

  • Page 1 If you have any questions, contact e fire department is being called. 3. Clean ventilating fans frequently. Lynx Grills, Inc. (888) 289-5969 Grease should not be allowed to d.You can fight the fire with your back accumulate on fan or filter.
  • Page 2: Installation Precautions

    IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION backdrafting. Follow the heating CAUTION - equipment manufacturer’s guidelines F. Install this hood in accordance with TO REDUCE THE RISK OF FIRE, and safety standards such as those all requirements specified by the ELECTRIC SHOCK, OR INJURY TO published by the National Fire manufacturer.
  • Page 3: Installation Planning

    INSTALLATION PLANNING CHECK THE INSTALLATION LOCATION CHOOSE THE INSTALLATION METHOD • If your installation has been roughed-in (including ductwork and ere are several different methods available to mount the hood: the wiring), be certain there are no obstructions in the way of the Unistrut, Angle Iron, Frame In, Wall Mount and Rough-In Plate Mount, mounting, pipes, other wiring, etc.
  • Page 4: Typical Installation

    ROUGH-IN PLATE MOUNTED 10" round duct transition rough-in plate ceiling hood lag screws filter grease trough 30" to 36" cooktop Figure A - Vertical Discharge TYPICAL INSTALLATION NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 5 STEP 1. INSTALLATION OF ROUGH-IN PLATE e hood unit is shipped with the rough-in plate and the transition attached. Note: e transition is shipped upside down Shipping Screws within the hood unit and must be removed and reinstalled. (See Figures 1 through 3.) Rough-in Plate 2.
  • Page 6: Step 2. Mounting The In-Hood Fan

    STEP 2. MOUNTING THE IN-HOOD FAN Instructions for mounting the LOHI fan into the TYPICAL INTERNAL FAN MOUNTING DETAIL LYNX wall hoods. 1. Install the fan by aligning the holes on the fan to the weld studs on the rough-in plate. Tighten...
  • Page 7: Step 4. Electrical Connection

    STEP 4. ELECTRICAL CONNECTION 1. Install three wires: black, white and green (#16 AWG) in 1/2" conduit from the service panel to the hood junction Power Supply box. Power supply must be rated for 120v, 60Hz, To Remote 15 amps (minimum). (if used) 2.
  • Page 8 STEP 5. INSTALLATION OF HOOD UNIT 1. Install the hood unit to the rough-in plate by aligning 3. If using internal fan LOHI, plug the fan Molex plug the weld studs on the rough-in plate with the slotted into mating hood Molex plug. holes on the back of the hood unit.
  • Page 9 USE AND CARE FILTERS Wash filters frequently either in a detergent solution, or by placing them in your dishwasher. Replacement filters may be purchased from Lynx. CONTROLS CLEANING Always turn the hood on before cooking to establish an air flow. Allow the fan to operate for a few minutes to clear Do not allow excessive grease to accumulate.
  • Page 10 IN-HOOD & REMOTE FANS LOHI IN-HOOD FAN 10" " 4" " " APPLICATION VOLUMETRIC FLOW RATE FOR EQUIVILENT DUCT LENGTHS Maximum CFM: 1200 LOHI FAN 1250 Duct Dimensions Electrical Motor Rating: 1175 10" dia. 8.0 Amps @ 115V AC, 60 Hz 9"...
  • Page 11 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 12: Cleaning Recommendations

    CLEANING RECOMMENDATIONS BRUSHED STAINLESS STEEL e Brushed Stainless Steel Hood should be cleaned with pre-washed flannel cloths and our recommended “Stainless Steel” cleaner. Always wipe in a manner which follows the grain. DO NOT clean with paper towels as they will scratch the surface. Different cleaning cloths other than cotton flannel may scratch the surface of the hood.
  • Page 13 Lynx reserves the right to change specifications or design without notice. Some models are certified for use in Canada. Lynx is not responsible for products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer.
  • Page 14 READ AND SAVE THESE INSTRUCTIONS Recommended for use only over conventional grills, and use with an approved Lynx hood. WARNING: Disconnect power before installing switch. Before turning power on, be sure that all controls are in the OFF position.
  • Page 15 CURB FOR FLAT ROOF WALL INSTALLATION ELBOW 5 1/2" 2" TRANSITION 28" 20 3/4" OUTSIDE WALL Fig. 2 Fig. 1 TYPICAL INSTALLATION DIRECT DUCT INSTALLATION ELBOW ELBOW ROUND TAPE JOINT DUCT ROOF ROOF ROUND DUCT TRANSITION 1/2" CONDUIT (NOT INCLUDED) Fig.
  • Page 16 I. MOUNTING REMOTE FAN LOHE ON ROOF OR OUTSIDE WALL Check to see if blower wheel turns freely. Do not replace top until installation is complete. e remote fan must be installed such that the exhaust/discharge is 12” minimum from the ground level. However, there are some local codes that do not permit this type of installation.
  • Page 17 III. WIRING A LOHE REMOTE VENTILATOR USING THE HOOD SPEED CONTROL 1. Power supply required for these ventilators is 15 amps. @ 120V. AC, 60Hz. connected per local codes. 2. Run three #14 AWG. wires (black, white and green) from the power supply at the electrical circuit panel to the hood J-box.
  • Page 18 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 19 5, For best performance duct runs should be as short and as straight as possible. Where turns are necessary, keep turning radius as large and as smooth as possible. ® ® FILE # 204107 Lynx Part # 0108E NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...

This manual is also suitable for: