A knock-out hole is provided on the cover plate of the electrical junction box to mount the fuse
and fuse holder. Be sure to comply with local codes on choosing the fuse and the holder.
Holder
(Field supply)
CAUTION
Before checking the operation of the air
conditioner, mount the electrical junction
box firmly by using 2 screws.
Supporting the box with only hooks and
slots is unstable, and may cause dropping
of the box.
When servicing the compressor, do not
tighten the compressor bolt too strongly as
this may damage the base pan.
Tightening torque should be less than
approx. 43 lbs.·in. (50 kgf.·cm.).
Knock-out Hole for Fuse
Fuse
(Field supply)
Knock out hole
Cover plate
(Junction box)
Electrical
junction box
Compressor
bolt
Cushion
rubbr
Hook
63
Slot
Base pan