CityGrow Systems CG800 Series User Manual

CityGrow Systems CG800 Series User Manual

Zigbee wireless switch

Advertisement

Quick Links

CG800 S
ZIGBEE WIRELESS SWITCH
U
M
SER
ANUAL
CG800S1
CG800S2
One Gang Switch
Two Gang Switch
CG800S2-CCP
CG800S4-CCP
One Gang Curtain
Two Gang Curtain
Control Switch
Control Switch
V
1.1
ERSION
17 J
, 2014
ANUARY
Disclaimers and Copyright
Nothing contained in this publication is to be construed as granting any right, by implication or otherwise, for the
manufacture, sale, or use in connection with any method, apparatus, or product covered by letters patent, or as
insuring anyone against liability for infringement of letters patent.
Efforts have been made to ensure the accuracy and reliability of the data contained in this publication; however,
Citygrow Energy Systems Limited. makes no representation, warranty, or guarantee in connection with this
publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or
from the use of any product or methodology described herein; for any violation of any federal, state, or municipal
regulation with which this publication may conflict; or for the infringement of any patent from the use of this
publication. Nothing contained in this publication should be viewed as an endorsement by Citygrow Energy Systems
Limited. of any particular manufacturer's products.
ERIES
CG800S4
Four Gang Switch
i
CG800DM
CG800DM2
One Gang Dimmer
Two Gang Dimmer

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CG800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for CityGrow Systems CG800 Series

  • Page 1 CG800 S ERIES ZIGBEE WIRELESS SWITCH ANUAL CG800S1 CG800S4 CG800S2 CG800DM CG800DM2 One Gang Switch Four Gang Switch Two Gang Switch One Gang Dimmer Two Gang Dimmer CG800S2-CCP CG800S4-CCP One Gang Curtain Two Gang Curtain Control Switch Control Switch ERSION 17 J , 2014 ANUARY...
  • Page 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 3: Table Of Contents

    Table of content Introduction ....................1 Understanding of the product ................ 2 Dimensions ....................3 Wiring-CG800S1, S2, S4, DM, DM2 ..............4 Wiring-CG800S2-CCP, S4-CCP ............... 6 Installation ....................7 Operation instruction ..................9 7.1. CG800S1, S2, S4 ................9 7.2. CG800DM, DM2 ................
  • Page 4: Introduction

    1. Introduction Thank you for buying Citygrow’s product. CG800 Series is both powerful and easy to use and install. These products are specially designed for Home Automation application. Description igBee wireless remote control. 2. Based on IEEE 802.15.4. 3. 2.4GHz radio frequency.
  • Page 5: Understanding Of The Product

    2. Understanding of the product Frame Button panel Front view Button panel Control bottom view button Connector to control unit Reset button Programming port Metal clip to fix the button panel Control unit bottom view Mounting hole Model number Control unit plate Front view Load terminals...
  • Page 6: Dimensions

    Load terminal to Model number chart Load terminals CG800S1 One Gang Switch Load1 CG800S2 Two Gang Switch Load1 Load2 CG800S4 Four Gang Switch Load1 Load2 Load 3 Load 4 CG800DM One Gang Dimmer Load1 CG800DM2 Two Gang Dimmer Load1 Load2 CG800S2-CCP One Gang Curtain Control Switch Motor 1 Motor 1...
  • Page 7: Wiring-Cg800S1, S2, S4, Dm, Dm2

    4. Wiring-CG800S1, S2, S4, DM, DM2 Situation 1: Live , Neutral and Load wires are ready at wall box Notes:The Neutral wire of load is closely connected to the Neutral point of CG800. Load terminals (See Table: 4A) Load Lamp Wall box CG800S1 Distribution panel...
  • Page 8 Table 4A Load terminals CG800S1 One Gang Switch Load1 CG800S2 Two Gang Switch Load1 Load2 CG800S4 Four Gang Switch Load1 Load2 Load 3 Load 4 CG800DM One Gang Dimmer Load1 CG800DM2 Two Gang Dimmer Load1 Load2 CG800S2-CCP One Gang Curtain Motor 1 Motor 1 Control Switch...
  • Page 9: Wiring-Cg800S2-Ccp, S4-Ccp

    5. Wiring-CG800S2-CCP, S4-CCP Notes:The Neutral wire of load is closely connected to the Neutral point of CG800. Neutral Live Conduit Curtain motor (AC) Wall box Load 1 Load 2 Wall Distribution panel Conduit CG800S2-CCP Wall box Load terminals (See Table: 4A) Before getting started WARNING! It must be installed by a qualified electrician in accordance with all applicable regulations and building codes.
  • Page 10: Installation

    6. Installation In order to install the product correctly, please follow the below steps: STEP 1: IMPORTANT! Turn off main power at the main switch board. STEP 2: Loosen the screws of the original wall switch. Remove the switch and disassemble the wiring.
  • Page 11 STEP 5: Push the ON/OFF Button to test whether the wiring has been connected correctly. If the ON/OFF Button does not function as expected, please check the wiring connection again. Notes: Use standard UK wall box BS4662; minimum 35mm deep. During installation of the wall box, it is recommended to embed the wall box deeper inside the wall in order to give more room to install the product.
  • Page 12: Operation Instruction

    7. Operation instruction 7.1. CG800S1, S2, S4 COVER PLATE 1. Cover BUTTON HOLDER 2. Label/LED Indicators 3. ON/OFF Buttons 4. Programming Port Master Kitchen 5. Reset Button 1. Press ON/OFF Button once to toggle between ON and OFF. BRIGHT LED indicates that the Switch is ON. DIMMED LED indicates that the Switch is OFF.
  • Page 13: Cg800Dm, Dm2

    7.2. CG800DM, DM2 COVER PLATE 1. Cover MAIN UNIT 2. Dim Up/ LED Indicator 3. Label/LED Indicator 4. Dim Down/ LED Indicator Foyer 5. Programming Port 6. Reset Button 1. Press the Dim Up/Dim Down button ONCE to Toggle between ON and OFF. LED FLASHING indicates that that the Button was pressed and dimming is in progress.
  • Page 14: Cg800S2-Ccp, S4-Ccp

    7.3. CG800S2-CCP, S4-CCP COVER PLATE 1. Cover BUTTON HOLDER 2. LED Indicator 3. Open/Close Button 4. Reset Button 5. Programming Port 1. Press the Open/Close Button once to control the electric curtain. - When the electric curtain is stopped, press the OPEN button to open the electric curtain.
  • Page 15: Setting The Open And Close Travel Distant For The Curtain

    7.3.1. Setting the open and close travel distant for the curtain. The function of the Learning Mode in the CG800S2-CCP or CG800S4-CCP is to program the duration of the curtain Opening/Closing time. In order to perform the Learning Mode function, please follow the below steps: STEP 1 Press the CLOSE Button until the curtain is fully closed.
  • Page 16 NOTE: The curtain should be opening at this point. STEP 4 Once the curtain is fully opened, press and release any Button. NOTE: The duration of the Opening/Closing time will be stored once the Button is pressed. STEP 5 Use a thin object to press the Reset Button again.
  • Page 17: Adding The Product To Your Home Wireless Zigbee Network

    8. Adding the product to your Home Wireless ZigBee Network STEP 1 Open the front cover, you will see a 5 pin connector programming port. STEP 2 Plug the CG101UT5 cable into the 5 pin socket of the product, and then plug the other end of the CG101UT5 cable into the mini USB end of the CG101UTC cable.
  • Page 18: Clear Memory

    9. Clear Memory Clearing the memory inside of the product will result in: 1. The product will no longer reply to any Panels that it had previously bound to. 2. The product will no longer reply to any Remotes that it had previously bound to. In order to perform the Clear Memory function, please follow the below steps: STEP 1 Press and HOLD anyone of the...
  • Page 19 STEP 4 Press and release the ON/OFF Button again to stop blinking. STEP 5 Press and release the Reset Button. The memory inside of the product has now been cleared.
  • Page 20: Specification

    10. Specification CG800S1 CG800S2 CG800S4 CG800DM CG800DM2 CG800S2- CG800S4 -CCP Description Four Gang One Gang Two Gang One Gang Gang Gang Switch Dimmer Dimmer Curtain Gang Switch Switch (Leading (Leading Control Curtain Edge Edge Switch Control Dimming) Dimming) Switch Load current (A) 5A x 2 2.5Ax4 600W...
  • Page 21 Two way control function Power supply AC 220-240V ,50Hz RF frequency 2.4GHZ 2.4GHZ 2.4GHZ 2.4GHZ 2.4GHZ 2.4GHZ 2.4GHZ Remote control distance 100M 100M 100M 100M 100M 100M 100M (M, line of sight) Dimensions mm (Length 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 87x87x39 x Width x Depth )

Table of Contents