STARTING THE GENERATOR (CONTINUED)
Starting the Generator Using Propane
34
1.
Shut breaker OFF
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
2.
Turn gas valve OFF
The gas valve is located above the recoil start on the bottom
of the fuel tank. Rotate the valve clockwise to the horizontal
position to stop the flow of gasoline to the carburetor.
3.
Connect propane hose and tank
The propane regulator is located on the frame of the
generator below the OHV valve cover. Ensure the propane
hose is securely connected to the regulator, then screw the
open ACME nut connection to your propane tank and turn
the tank on.
4.
Turn idle control OFF
The idle control is located on the top center of the main
power panel. Turn the switch "OFF" to prevent the unit from
trying to idle down before the engine is warmed up.