GLASS DOORS
Glass doors are optional with this fireplace. When fireplace is in
operation, doors must be fully opened or fully closed position only
or a fire hazard may be created (see Figure 23).
A fireplace equipped with glass doors operates much differently than
a fireplace with an open front. A fireplace with glass doors has a
limited amount of air for combustion. Excessive heat within fireplace
can result if too large a fire is built or if combustion air gate is not
completely open.
The following tips should be used to assure that both fireplace and
glass door retain their beauty and function properly. Both the flue
damper and glass doors must be fully opened before starting a
fire. This will provide sufficient combustion air and maintain safe
temperatures in firebox.
IMPORTANT: The glass must be allowed to warm slowly and evenly.
Tempered glass will withstand a gradual temperature rise to 550°
F, which is more than a normal fire will generate. Such materials as
pitch/wax laden logs, very dry mill end lumber and large amounts
of paper or cardboard boxes can create an excessively hot fire and
should not be burned in this fireplace. Always keep fire back from
doors and never allow flames to contact glass.
" WARNING: FIREPLACES EQUIPPED WITH DOORS
SHOULD BE OPERATED ONLY WITH DOORS FULLY
OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT
PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT
OF THE FIREPLACE OPENING, CREATING RISKS OF
BOTH FIRE AND SMOKE".
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 23 - Glass Doors
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water. Do
not use any abrasive material to clean the glass. Do not clean glass
with any cool water if glass is still hot from fire and smoke.
OUTSIDE AIR AND DAMPER HANDLE OPERATION
The damper handle, which opens and closes the damper blade, is
located in upper front face of fireplace. Pushing handle into the left
of keyway slot will free damper blade to automatically open. Pushing
handle into the right will lock damper blade closed.(see Figure 24).
14

OPERATION AND MAINTENANCE

Vent damper must be locked in the full open position before operat-
ing fireplace.
Outside air kit handle is located at left hand side of fireplace (see
Figure 24). Pulling handle out will free outside air door to open.
Pushing handle in will lock door closed.
WARNING: Risk of fire! Replace grate with IHP
model 109910-01 only. This grate has been designed to
keep the operation of your fireplace safe and efficient.
LOCATING ACCESS COVER PLATE
Sheet metal cover plates located underneath front hearth refractory may
have shifted or moved out of place while fireplace was in transit. These
cover plates must be kept in the proper location prior to using the fireplace
(See Figure 25).
For further operating guidelines, instructions and warranty informa-
tion, please refer to your homeowner's guide or contact your dealer.
Superiorfireplaces.US.com
Damper
Handle
Outside Air
Handle
Kit Handle
Retainer
Figure 24 - Damper and Air Kit Handle
Access
Panel
Figure 25 - Locating Access Cover Plate
Keyway
Slot
126619-01D