Canon EOS 55 Service Manual page 161

Table of Contents

Advertisement

Part 3: Repair Information
Temperature Compensation
@4'i•r~;;-.---------Afl_o_w_th_e_~;;;;;-ii;;--m-1-·n_u_t_~;-~~~t-ti~;-;ith--th;--~~-tc_h_o_ff_b;f~~~----------------1
continuing with this procedure.
:
-------------------------
______________
. .
PROCEDURE:
Press the F4 key to display this screen,
showing the room temperature measured by
the HS-1/F and the temperature measured
by the camera. Check whether there is a
difference of more than 3°C between the
two.
If
so, press the Return key to display the
next screen showing the room temperature
measured by HS-1/F. Check whether the
room temperature is normal.
If
so, press
the Return key to return to the data transfer
menu screen.
If
not, press the Space key to move the cur-
sor to the position of the room temperature.
Then, press the numeric keys to enter actu-
al room temperature measured with a ther-
mometer.
Press the Return key to display the next
screen , showing the room temperature
measured by HS-1/F and the temperature
measured by the camera. Check whether
there is a difference of more than 3°C
between the two.
If
so, press the Space key to correct the
room temperature again.
If
not, press the
Return key to the data transfer menu
screen.
3-70
TEMPl
Temperature
Com ensation
TEMP2
Room and camera temperatures are:
If difference
>
5, compensation is
required.
Press RETURN to proceed.
Press SPACE bar for DATA TRANSFER
Menu Screen.
Temperature
Compensation
TEMP)
Set the temperature compensation.
Present Temperature
CRoom7
Press RETURN for automatic compensation.
Press SPACE bar and type in temperature
for manual compensation.
Temperature
Compensation
C Room 7
~[ _came-ra ~]
If difference
>
5, compensation is O.K.
If 0. K.,
press
RETURN.
If N.G.,
press
SPACE bar and readjust.