Page 1
Keep for the entire life of the product REFRIGERATION CABINET CAPRI (with undermount refrigerating unit placement) Capri 0,5С OPERATING MANUAL ATTENTION! READ AND UNDERSTAND THIS MANUAL BEFORE INSTALLATION AND THE FIRST USE OF THE DEVICE. DEVICE’S SAFETY AND COMMERCIAL IMPACT HIGHLY DEPEND ON FOLLOWING THE REQUIREMENTS IN THIS DOCUMENT.
INTRODUCTION This Operating Manual (hereinafter referred to as Manual or RE), that also includes certifi- cate data, applies to series of Capri refrigerated wall-sited undermount cabinets (hereinafter re- ferred to as cabinet or device). Data listed below provides information as well as guidelines for consumers and maintenance specialists regarding: −...
CUIT! 1. 9. The manual does not reflect some minor manufacturer-introduced modifications to the device. 2. TECHNICAL SPECIFICATIONS Main technical specifications of the device are as specified in table 1. Table 1 Parameter name Capri 0,5S Inner volume, m3 0,58...
Effective volume, m3 0,53 Effective volume temperature with environment temperature 25° and from 0 to plus 7 relative humidity level 60%, °C The temperature increase in the products stored in the effective refrigerated volume during defrosting, max °C Refrigerated area on rack-shelves, excluding the bottom area, m2 Energy consumption per day, maximum kW/h - R134a...
Page 5
with manufacturing № meets all tech- nical requirements of TY 28.25.13-002-07600499-2017 and is evaluated as suitable for opera- tion. The unit is packed with accordance with technical documentation The electric circuit rated for voltage of ~220V. Release date № Compressor Refrigerant brand and volume Chief Quality Inspector (Signature)
Page 6
5. 5. When placing the device, leave at least 100mm gap between the wall and de- vice's back wall. Do not install the device closer than 2 meters from the heating units, under direct sunlight, air drafts, caused by opening doors, windows or artificial climate (creating air flows stronger than 0.2m/s) or in premises with humidity level surpassing the limits set in article 1.3.
Page 7
OPERATION AND MAINTENANCE MANUAL 7. 1. Following the operating rules and requirements set forth in this manual will increase the life and safety of the device. 7.2. After checking the technical specifications and electrical safety of the device, connect it to the power grid, following the rules above.
Page 8
air-proof material. Failure to follow these rules inhibits air circulation, lowers operation characteris- tics of the device which might spoil the food items. DO NOT STORE EXPLOSIVE ITEMS, SUCH AS AEROSOL SPRAYS WITH IN- FLAMMABLE LIQUIDS. DO NOT STEP ON OR INTO THE PRODUCT TO AVOID DEFORMATION OR TIPPING OF THE PRODUCT.
Page 9
c) Check the lighting; d) check automatic defrosting system in the evaporator and condensate draining sys- tem. e) clean the condenser from dust and dirt; f) check the integrity of the refrigeration system; g) make sure that the leak current is below 3,5mA. When performing procedures a, b, c, d, e, f and g disconnect the device from the power grid, by unplugging it.
9. MAINTENANCE RECORD. WARNING: INSTALLATION, COMMISSIONING, TECHNICAL MAINTENANCE AND REPAIRS SHOULD BE PERFORMED BY SPECIALISTS TECHNICIANS FROM A SPECIALISED ORGANIZATION (SERVICE PROVIDER) IN A STRICT COMPLIANCE WITH STANDING LABOR SAFETY STANDARDS. DO NOT MAKE ANY ALTERA- TIONS IN THE PRODUCT DESIGN. WARNING! В...
Page 12
LIST OF POSSIBLE MALFUNCTIONS AND FIXES Table 4. Defect name, external and other signs Probable reason How to fix 1. Device is connected to the power grid but not working. No power in the wall outlet. Check the voltage in the wall outlet. 1.1.
Page 13
3.3. Megohmmeter shows Interwinding short circuit in Disassemble terminal block and test short-circuit between starting the electric compressor en- the output for continuity to discover and operating winding when gine. any shorting. If the compressor is connector blocks are removed. damaged, replace it.
Page 14
The device is loaded with Defrost the evaporator. Load the warm products. device with pre-cooled (frozen). No space between the loaded Make space between the loaded products and the enclosure. products and the enclosure. Air cooler fan does not work Check the contacts.
10. MANUFACTURER WARRANTY 11. 1. Warranty period is 12 months from the date of selling the device, but not longer than 18 months from the manufacturing day. 11. 2. During the warranty period, service providers will perform all diagnostics and replace defective components. 11.
Page 16
11. 11. In case of the Buyer's neglect to observe the above-mentioned articles, the manufacturer will have the right to immediately interrupt the warranty without further notice. 11. 12. This warranty does not infringe upon the consumer's right, granted by legislation.
Page 18
APPENDIX B Medium temperature refrigeration cabinet Capri 0,5S Basic circuit diagram. А1 – Compressing-condensing block; А2 – controller; EL1, EL2 – LED strip; М – evaporator fan; RK1 – temperature sensor; SA – lighting switch; U – LED strip power source; XP – power cord with a plug.
Need help?
Do you have a question about the CAPRI 0,5S and is the answer not in the manual?
Questions and answers