3. Installation Preparation - Read
Before Beginning Installation
For correct and safe installation, please read these
instructions completely.
The grounding of electrical equipment such as
telephone, computers, etc., to water lines is a
common procedure. This grounding may be in the
building, or may occur away from the building. This
grounding can cause electrical feedback into a
water chiller, creating an electrolysis which causes
a metallic taste or an increase in the metal content
of the water. This condition is avoidable by using the
proper materials. Drain fittings which are provided by
the installer should be plastic to electrically isolate the
chiller from the building plumbing system.
Warranty is void if installation is
NOTICE
not made in accordance with
current instructions.
• Hose sets are not to be used for connecting to
water mains.
• Always shut off the valve at the installation/ service
area to reduce risk of water damage.
• Thoroughly flush all water lines and fittings of all
foreign matter before connecting to chiller.
• If inlet pressure is above 100 psig (0.69 MPa),
a pressure regulator must be installed in water
supply line. Any damage caused by the water
pressure outside its rated pressure is not covered
by warranty.
5. Ratings
5.1 ER2 Series
Description
Electrical
Ambient Air Temp.
Water Pressure
Maximum Water Temp.
Refrigerant
Ingress Protection
Use
(630) 574-8484
2000000700 (Rev. A - 07/22)
ER2_1G ER2_2G
115VAC, 60Hz, (See nameplate
for Amperage), 1 phase
50-90 °F (10-32 °C)
20-100 psig (0.14-0.69 MPa)
90 °F (32 °C)
HFC-R134a
For Indoor Commercial Use only

4. Tools and Supplies

4.1 Tools Required
Tool
Phillips Screwdriver
Various Electrician's
Hand Tools
Various Plumber's
Hand Tools
3/32 Allen Wrench
4.2 Installer-Supplied Parts
1/4" (6.4mm) Socket Wrench or Flat Head
Screwdriver
Water Shut-off Valve
Additional fasteners
4.3 Tools/Items required but not provided
Safety glasses
Protective gloves
Hex driver
ER2
220/240VAC, 50Hz, (See
nameplate for Amperage), 1 phase
IP20
Page 7
Used For
Remove electrical box cover
Connecting power source to the unit's
wiring
Connecting unit's plumbing to the
household water source and waste
drain
Remove the front covers
Description
Description
Elkay Manufacturing Company
Qty.
1
1
Qty.
1
1
1