Electrolux FC48 Installation Manual page 20

Finishing cabinet
Table of Contents

Advertisement

05306004
1004
Notice
Date
TABLE OF CORRESPONDENCES - Finishing cabinet FC48
Category
Type
index
of
gas
*2E, 2H, G 20
2ESI
2L, 2ESI G25
3 P
G31
3 P
G31
* For Belgium, no work is allowed between G20 and G25.
**8 min typical cycle : 8 60/40 polyester-coton overalls of 550g, 61% retention rate, "high" drying temperature (85°C), with no cool
cycle, unit preheated for 3 min. at 85°C, loading/unloading time estimated at 2 min.
Note : G20 (H) = natural gas, Lacq type (20 mbar)
G25 (L) = natural gas, Groningue type (20 or 25 mbar)
G31 = propane gas (37 or 50 mbar)
8
6
Page
Working
supply
Hi
pressure
in mbar
20
34,02
MJ/m³
25
29,25
MJ/m³
37
46,34
MJ/kg
50
46,34
MJ/kg
IMPORTANT
Tightness test after installation
The gas leak test is performed as follows :
1/ Paint pipe joints, pilot gas tubing connections and inspect outlets
with rich soap and water solution ; do not use an aggressive soap.
2/ Put the machine into service. Bubbles indicate a gas leak.
3/ Eliminate this leak.
NOTE : After all intervention, re-seal (red varnish) the following
adjustment organs :
- regulator of pressure.
In case of changing of gas, the stick for the adjustment has to be
modified.
Check-out
Before leaving, put the appliance into operation and allow to run a
complete cycle. Watch to ensure that all burner system components
function correctly.
6. Installation/
Putting into service
Ø of
Pressure at
injectors
injectors
in mm
3,30
184 mmH
O
2
or 18 mbar
3,70
184 mmH
O
2
or 18 mbar
2,20
regulator out
of operation
2,10
regulator out
of operation
INSTALLATION
MANUAL
Heat
Consumption
emission
Qn in kW
Mn in
(Hi)
kg**
20
-
20
-
20
0,16
20
0,16
Consum-
ption
Vn in
m³**
0,23
0,27
-
-