  • Page 1 Professional Series Technical Manual Model 5306 Mixer/Preamplifier...
  • Page 2 Index Specifications* Professional Division Warranty J B L Model 5 3 0 6 Mixer/Preamplifier installation O p e r a t i o n Service Notes Maximum Gain A p p e n d i x Microphone 86 d B , + 2 d B Program 40 dB, + 2 dB Output Level...
  • Page 3 The unusual affected b y strong magnetic fields. For this reason, it is dynamic range o f the 5306 results f r o m a preamplifier circuit recommended that the 5306 be located at least seven inches...
  • Page 4 Connections Output Connections i n p u t Program—The program channels are wired for unbalanced The o u t p u t transformer has a split secondary winding t o permit 50,000-ohm operation and are equipped w i t h both screw 600-ohm or dual 150/600-ohm connections.
  • Page 5: Operation

    A n y additional connection between the circuit and chassis or ground may cause h u m . Output—When the balanced o u t p u t of the 5306 is connected t o a power amplifier that does not have an isolation transformer, the circuit-to-chassis connection at the power amplifier must be removed.
  • Page 6: Total Harmonic Distortion

    Using the test set-up illustrated, replace the A C voltmeter The f o l l o w i n g test equipment is recommended: w i t h the harmonic distortion analyzer at the 5306 o u t p u t terminals.
  • Page 7 Connect the analyzer input terminals across the 600-ohm balanced o u t p u t terminals of the 5306. The o u t p u t of the mixer should be properly loaded w i t h a 620-ohm, 1-watt resistor.
  • Page 8: Output Amplifier

    22.0V 44.5V might suggest a source of trouble. Q409 22.0V 43.4V Q410 43.4V 43.9V Testing—All of the major circuits used in the 5306 are connected Q411 43.8V 44.2V *22.3V in cascade; consequently, each successive unit must operate Q412 1.2V *22.3V properly in order t o test the following stages.
  • Page 9: Line Amplifier

    The signal levels indicated in the table are based on an input signal of 1000 Hz at .5 mV applied to any one of the six microphone inputs of the 5306. A C Test Voitages Amplifier...
  • Page 10 Appendix Microphone Preamplifier Assembly Mixer Assembly...
  • Page 11 J B L M o d e l 5308 Expander Major Parts Schematic References J B L Number Part Number Description Transformers 5308 optional 8-channel e x p a n d e r Power Transformer T301 48400 O u t p u t Transformer T302 47608...
  • Page 12 J B L M o d e l 5 3 0 6 M i x e r Parts not normally available through supply houses can be ordered from: C u s t o m e r S e r v i c e J a m e s B .
  • Page 13 PFI) \0QO A C C O ^ I ^ P v T CO A *...