DIP S
S
WITCH
ETTINGS
Thermostat
Selection
Switches
Heating Fan
Off Delay
Heating
CFM
Switches
Cooling
CFM
Switches
Cooling
CFM
Switches
Heating
CFM
Switches
Continuous
Fan CFM
Switches
Thermostat
Selection
Switches
Heating Fan
Off Delay
PCBBF137 CONTROL BOARD DIP SWITCHES
1
S1
2
3
4
1
S3
1
2
2
1
3
S2
2
3
PCBBF139 CONTROL BOARD DIP SWITCHES
1
S1
2
3
4
1
S2
2
3
4
1
S3
2
3
4
DIP
DIP
Swi tch
Swi tch
Purpos e
Group
Number
Hea t
1, 2
Sta gi ng /
Del a y
S1
Bl ower
3, 4
Hea t Off
Del a y
* = Fa ctory Pos i ti on
Switch
Purpose
Group
Thermostat
1 Stg Stat 10 min delay
S3
Setup
1 Stg Stat 20 min delay
Heating Fan
S3
Off Delay
* FACTORY
SETTING
34
Functi on
Auto
1 OFF*
2 ON*
10 Mi nutes
1 ON
2 OFF
20 Mi nutes
1 ON
2 ON
2 Sta ge
1 OFF
2 OFF
90 Seconds
3 OFF
4 OFF
120 Seconds
3 OFF
4 ON
150 Seconds
3 ON*
4 OFF*
180 Seconds
3 ON*
4 ON
Dip Switch
Function
1
2
2 Stage Stat
OFF
OFF
ON
OFF
ON
ON
Auto
OFF*
ON*
90
OFF
120
OFF
150
ON*
180
ON
3
4
OFF
ON
OFF*
ON