Operating Your Qtac; Before Starting Up Your Qtac; Pump Operation; Priming The Pump After An Extended Period Of Use - QTAC 85HPK Owner's Manual

Table of Contents

Advertisement

OPERATING YOUR QTAC

Before Starting Up Your QTAC

Always wear appropriate eye, ear, and body protection when operating your
QTAC unit.
Ensure that your QTAC has sufficient water in the water tank prior to operation.
The water level can be checked by viewing the water tank site gauge located on
the side of the water tank (Figure 1, Item 5) If the water tank is low on water,
open the water tank fill tower (Figure 1, Item 3)and fill the water tank with water.
Check the pump engine fuel(Figure 3, Item 1) and oil levels (Figure 3, Item 5) as
needed, fill the pump engine with fuel and oil as specified in the engine manual
that came with your QTAC. For more information, see the Pump Operation
Manual and the Honda Owner's Manual.

PUMP OPERATION

Priming the Pump after an Extended Period of Use

The QTAC pumps are a self-priming pump, meaning they do not need to be primed
before every use. However, if the pump is being started after not being in use for more
than 12 hours, it may be necessary to add water to the primer port (Figure 2, Item 2) to
ensure proper suction. To do so, simply pour water into the primer port until it is full,
secure the cap and start the engine.

Tank Fill Requirements:

MAX FILL PRESSURE: 100 PSI
MAX FILL RATE: 150 GPM
Page | 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

85hp85s125s125hp125hpk

Table of Contents