  • Page 1 INDOOR COOKING Vent Hood – Pro Canopy Installation, Use and Care Manual...
  • Page 2 SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR GUIDANCE. ALL OTHER SERVICING SHOULD BE DONE BY A HESTAN AUTHORIZED SERVICE TECHNICIAN. READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE INSTALLING OR USING YOUR APPLIANCE TO REDUCE THE RISK OF FIRE, BURN HAZARD, OR OTHER INJURY.
  • Page 3 From ranges to refrigeration, every detail is designed to deliver the performance and reliability expected in a restaurant – now available for you. We appreciate you choosing Hestan, and we promise to deliver the very best to you. Welcome to Hestan...
  • Page 5: Table Of Contents

    LIMITED WARRANTY SAFETY PRECAUTIONS - BEFORE YOU BEGIN When properly cared for, your Hestan ventilation system will provide safe, reliable service for many years. When using this ventilation system, basic safety practices must be followed as described in the following pages.
  • Page 6: Safety Precautions - Before You Begin

    GENERAL SAFETY PRECAUTIONS GENERAL SAFETY PRECAUTIONS When properly cared for, your new Hestan ventilation hood has been designed to be a safe, reliable ventilation system. Read all instructions carefully before using this ventilation system. When using kitchen appliances, basic safety precautions must be followed.
  • Page 7 This ventilation system is intended for use with ranges or cooktops, which can get very hot during operation. Observe the warnings and cautions for the cooking appliance. This ventilation system should be serviced only by a Hestan authorized service technician. Contact the nearest authorized service center for examination, repair or adjustment.
  • Page 8: Model Numbers

    * Static Pressure in inches water column. ** When comparing the Hestan system with blower units made by other manufacturers, use the “Equivalent CFM”. *** Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.
  • Page 9: Regulatory / Code Requirements

    (facing the knob). Rotate the knob counter-clockwise to dim the lights or turn them off. Controls for two blowers Item Function Blower control Light control Controls for three and four blowers Blower control blowers 1 & 2 Blower control blower 3 or blowers 3 & 4 ©2020 Hestan Commercial Corporation...
  • Page 10: Cleaning And Maintenance

    1. Unsnap two suitcase latches, one on each side of the housing. 2. Support the housing and pull it away from the blower base. 3. While pulling it back, gently “tip” it downward to clear the blower wheel(s). ©2020 Hestan Commercial Corporation...
  • Page 11 If grease build-up should occur, the blower wheel may easily be cleaned in place using a soft bristle toothbrush and a common degreaser such as Formula 409®. Take care not to move or lose the metal balancing clips that may be affixed to the wheel. Item # Description Balancing clip Blower wheel ©2020 Hestan Commercial Corporation...
  • Page 12 For hoods that have more than one blower wheel, make sure that white blower wheels are matched up with white motor rings, and black blower wheels are matched up with black motor rings. The hood will not perform properly if blower wheels and motors are mismatched. ©2020 Hestan Commercial Corporation...
  • Page 13: Troubleshooting

    Are the motor and wheel assemblies installed in the correct locations? • Check the damper doors in blower housing(s) - do they move/open freely? • Check the dampers/vents to outside - do they open freely, with no obstructions? • Check for damaged or obstructed ductwork. ©2020 Hestan Commercial Corporation...
  • Page 14: Ducting Do's And Don'ts

    Proper combining Smooth duct Smooth gradual turn loaded doors on wall louvers or roof of two ducts caps. Do not terminate venting into an attic or chimney. Improper combining Flexible duct Sharp angled turns of two ducts ©2020 Hestan Commercial Corporation...
  • Page 15: Installation

    Hestan duct covers will be used. • NOTE: Since Hestan duct covers can be opened for access, they can 30” be installed with the hood and still permit access to connection [76.2 cm]...
  • Page 16 The end of the duct(s) should extend 1” below the ceiling. • Use foil HVAC tape (not grey cloth duct tape) to seal all joints. See “VENT ACCESSORIES” on page 18 for a listing of available Hestan ducting materials. TRANSITION HEIGHTS: TRANSITION HEIGHTS: Dual Blower (WM2L = 600 CFM): none - 8”...
  • Page 17 It is not necessary to remove the blower wheel from the motor. a) Remove the three screws retaining the blower motor. b) Pull the motor out far enough so you can reach its electrical connector. c) Unplug the connector, set the blower motor and screws aside. ©2020 Hestan Commercial Corporation...
  • Page 18 Using proper hardware, attach the mounting strip to at least two wall studs. Note: for 48” and larger hoods, three screws into studs are recommended. ©2020 Hestan Commercial Corporation...
  • Page 19 14. Mounting the Hood: FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 15. • If using a Hestan duct cover, it must be mounted to the hood using the provided fasteners before continuing. Method a) Place the appropriate elbow(s) on the top of the hood.
  • Page 20 Step 11) into the pilot holes drilled in Step 13. 16. If a Hestan duct cover is used, it should be secured to at least one stud using the nailing strips. The duct cover front panel should then be installed.
  • Page 21 Standard 8” [20.3 cm] round - 10 3/4” [27.3 cm] 8” Round 12” 8 ½” [30.5 cm] [21.6 cm] 6” [15.2 cm] 8” Round 16” [20.3 cm] [40.6 cm] Low profile elbow: 8” to 6” x 8-1/2” Side View Hestan P/N AKVBE8 ©2020 Hestan Commercial Corporation...
  • Page 22: Vent Accessories

    6-½” 10-½” 16-¾” 22-½” 16-¾” 20-¾” MODEL DESCRIPTION MODEL DESCRIPTION AKVRC6HP 6” Round AKVRC10HP 10” Round AKVRC8HP 8” Round AKVRC12HP 12” Round THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE. ©2020 Hestan Commercial Corporation...
  • Page 23: Duct Covers

    -OR for Citra - Orange -BG for Tin Roof - Burgundy -PP for Lush - Purple -BU for Prince - Blue -GR for Grove - Green -GG for Pacific Fog - Graphite Gray -TQ for Bora Bora – Turquoise ©2020 Hestan Commercial Corporation...