Operating Guidelines And Maintenance Instructions - Heat & Glo GRL-850-AU Installation And Operation Instruction Manual

Table of Contents

Advertisement

STEP 9: LOG #7 (SRV571-707)
Place log #7 in the groove on log #1 with its front resting on log #4.
3.0 OPERATING GUIDELINES AND
MAINTENANCE INSTRUCTIONS
Upon completing the gas line connection, a small
amount of air will be in the lines. When fi rst lighting the
pilot light, it will take a few minutes for the lines to purge
themselves of this air. Once the purging is complete,
the pilot and burner will light and operate as indicated
in the instruction manual. Subsequent lighting of the
appliance will not require such purging.
WARNING: BE SURE FIREPLACE SCREEN
!
OR GLASS DOORS ARE IN PLACE WHEN
BURNING FIREPLACE LOGS. UNLESS
OTHER PROVISIONS FOR COMBUSTION AIR
ARE PROVIDED, THE SCREEN OR DOORS
SHALL HAVE AN OPENING FOR INTRODUC-
TION OF COMBUSTION AIR. THIS GAS LOG
SET IS NOT DESIGNED TO OPERATE WITH
AIR TIGHT GLASS DOORS. IF GAS ODOR IS
NOTICEABLE, TURN CONTROL KNOB TO
"OFF" POSITION AND CHECK ALL CONNEC-
TIONS FOR LEAKS. DO NOT USE OPEN FLAME.
ADEQUATE COMBUSTION AND COOLING AIR
MUST BE PROVIDED OR THE UNIT WILL NOT
FUNCTION PROPERLY.
The following conditions must not cause spillage of
combustion products:
• cold chimney or fl ue system
• open or closed doors or windows
• operation of any exhaust or extraction fans
• operation of any other gas appliance in the room or
dwelling
Proper means must be employed to ensure suffi cient
draft.
Note to Installer: Disconnect this appliance and advise
owner if any spillage or abnormal operation occurs
10
7
Heat & Glo • GRL-850-AU, GRL-850LP-AU • 2011-900 Rev. i • 8/10
trouble free operation. When the appliance is put back
in service, check the burner fl ame patterns.
The appliance and venting system should be inspected
before initial use and inspected and cleaned at least
annually by an authorized fi eld service person.
PILOT
FLAME
Figure 3
which can't be rechecked immediately.
To obtain proper operation, it is imperative that the pilot
and main burner fl ame characteristics are steady, not
lifting or fl oating. The thermocouple should be engulfed
in the pilot fl ame (see Figure 3).
Periodically examine the area around the burner neck
and the pilot. Any dirt or lint in this area should be
removed. Confi rm the proper air shutter setting as
shown in Table 1 below. This will ensure long life and
TABLE 1.
BURNER
GRL-850-AU
7
THERMOCOUPLE
NG
LP
9.5 mm
FULL OPEN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grl-850lp-au

Table of Contents