Technical Specifications - Presys DCY-2050 Manual

Universal process controller
Table of Contents

Advertisement

PRESYS
| Instruments

1.3 - Technical Specifications

Inputs:
Two thermocouple configurable inputs (J, K, T, E, R, S, under ITS - 90), RTD Pt
- 100 under DIN 43760, 4 to 20mA, 0 to 55mVdc, 1 to 5Vdc, 0 to 10Vdc. Input
impedance of 250 Ω for mA, 10M Ω for 5Vdc and 2M Ω above 5Vdc. Table 1 shows
the temperature range limits for thermocouple and RTD and the resolution for the
linear input sensors.
Input sensor
Thermocouple
RTD
Linear
(*) including wire resistance
Control functions:
* ON-OFF Control.
* PID Control.
* PID Control with AUTO-TUNE.
* Heating-cooling Control.
Type J
Type K
Type T
Type E
Type R
Type S
Pt-100 2- or 3-wire
Voltage
Current
Table 1 - Input Sensor Measuring Span
DCY-2050 and DCY-2051
lower
higher
limit
limit
°F
°F
-184.0
1886.0
-346
2498
-418
752
-148.0
1436.0
-58
3200
-58
3200
-346.0
1256.0
Span
0 to 55mV
0 to 5V
0 to 10V
0 to 20mA
* Reason Control.
* Cascade Control.
* Remote set-point input
* Programmable set-point
Span
lower
higher
limit
limit
°C
°C
-120.0
1030.0
-210
1370
-250
400
-100.0
780.0
-50
1760
-50
1760
-210.0
680.0*
Resolution
6μV
500μV
1mV
2μA
Introduction