Advertisement

Quick Links

CMT2310A-EB Evaluation Board Operation Guide
Overview
This Document introduces how to operate the CMT2310A-EB evaluation board (factory default firmware). The
CMT2310A-EB (factory default firmware) and CMT2310A-EM help users quickly evaluate the performance of
the CMT2310A. Meanwhile, CMT2310A-EB can help users to debug, verify and test the CMT2310A functions,
basing on the hardware as a general CM0 level single chip development board.
Part number covered in this document is shown as follow.
Part Number
CMT2310A
113 – 960 MHz
Reading guideline:
1. Before reading this document, it is advised to read the CMT2310A Data manual first to understand the
functions and performance of the CMT2310A.
2. When using the evaluation board, please refer to the following related AN for further understand the
CMT2310A function configuration options:
a)
AN235 CMT2310A FIFO and Packet Format Useage Guide
b)
AN236 CMT2310A Register Description
c)
AN237 CMT2310A Quick Start Guide
d)
AN238 CMT2310A RF Parameter Configuration Guide
e)
AN239 CMT2310A Auto-transceiver Usage Guide
Copyright © By HOPERF
Table 1. Part number covered in this document
Freq.
Demodulation
(G)FSK
Function
High performance RF
transciever
V0.4 | Page 1/41
AN241
Configuration
Register
AN241
Package
QFN24
www.hoperf.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMT2310A-EB and is the answer not in the manual?

Questions and answers

Summary of Contents for CMOSTEK CMT2310A-EB

  • Page 1 CMT2310A-EB (factory default firmware) and CMT2310A-EM help users quickly evaluate the performance of the CMT2310A. Meanwhile, CMT2310A-EB can help users to debug, verify and test the CMT2310A functions, basing on the hardware as a general CM0 level single chip development board.
  • Page 2: Table Of Contents

    AN241 Table of Contents Hardware Platform Introduction ......................3 CMT2310A-EM Introduction ......................3 CMT2310A-EB Introduction ......................5 Parameter Setting .............................7 Startup Interface ..........................7 Main Menu ............................8 Modulation Submenu ........................9 Work Mode Submenu ........................10 Frequencry Band Submenu ......................11 Data Rate Submenu ........................
  • Page 3: Hardware Platform Introduction

    The CMT2310A evaluation board hardware test platform is composed of CMT2310A-EB and CMT2310A-EM:  CMT2310A-EB is the test panel of the evaluation board, using HC32L136 as the development board of the CMT2310A module, factory set with CMT2310A function and performance evaluation firmware, and can also be used as the CMT2310A development board.
  • Page 4 AN241 Table 1-1. CMT2310A-EM Description Function Description CMT2310A has an embedded DC-DC module. You can select the DC- DC mode or disable it. Noted that this jumper is a hardware choice and needs to combine with the control software. If you want to enable the DC-DC Select DC-DC module, the software also needs to configure the corresponding register BUCK_SEL to 1 (located in Page1, address...
  • Page 5: Cmt2310A-Eb Introduction

    LED2 LED3 PC13 VCAP 5. Buzzer 7. Reset Key 6. User Interface (LCD, LED, Key) Figure 1-2. CMT2310A-EB Introduction Table 1-2. CMT2310A-EB Description Function Description Connect the 10PIN base of CMT2310A-EM and connect the HC32L136 control pin as CMT2310A-EM Connector...
  • Page 6 1. For more information of CMT2310A-EB, please refer to its schematic diagram - CMT-RF_EB revXXX SCH.pdf In summary, CMT2310A-EB can be regarded as a development board with HC32L136 as the main control, which provides a variety of user-computer interaction interfaces (LCD lattice, beeper, LED, keys, USB-to- UART bridge, etc.).
  • Page 7: Parameter Setting

    AN241 2 Parameter Setting Based on CMT2310A-EB and CMT2310A-EM, a firmware for testing and evaluation of multiple functions of CMT2310A chip will be pre-burned at the factory. This firmware will be updated according to functional changes. You can download it from the official website of Hope Microelectronics Co., LTD., and use the J-link debugger and use J-Flash software for burn update (Chapter 4 of this article will describe the firmware update in detail).In the following section, parameter setting menu of the factory firmware will be described in detail.
  • Page 8: Main Menu

    AN241 not found CMT2310A Figure 2-2. Startup Interface(not inserted CMT2310A-EM) 2.2 Main Menu After the screen is powered on for about 1 second, the screen will switch to the normal menu mode, as shown in Figure 2-3 below. (If the CMT2310A-EM is not inserted properly or the CMT2310A chip cannot be identified, the screen will remain in the display state as shown in Figure 2-2 until CMT2310A-EM is inserted properly or CMT2310A can be recognized normally.) CM T2 31 0A EB GU I...
  • Page 9: Modulation Submenu

    AN241 Function Description Coding Format(Coding format selection) CRC Select(CRC verification mode selection) 10. Freq Space(Frequency offset interval setting) 11. Freq Channel(Frequency channel signal setting) 12. DC-DC Select(DC-DC mode selectio) 13. Gaussian Select(Gaussian mode selection) 5 buttons shown in this area with corresponding key of K1-K5 :it is corresponding to K1,indicates that CMT2310A EB will enter the working state according to the parameters/modes set in the above menus as short pressed;...
  • Page 10: Work Mode Submenu

    AN241 Figure 2-4. Modulation Submenu Interface Function Description 3 modulation modes can be selected by pressing K3 or K4 in the area:   2FSK Rolling option area  4FSK After selecting the corresponding modulation mode, press K2 or K5 to confirm the selection and return to the upper menu (i.e.
  • Page 11: Frequencry Band Submenu

    AN241 2.5 Frequencry Band Submenu Select the 3 Frequencry Band and press K5 to enter the submenu, as shown in Figure 2-6. CM T2 31 0A EB GU I 3 Fre que ncr y B and 1. Rolling option area 43 30 00k Hz Figure 2-6.
  • Page 12 AN241 CM T2 31 0A EB GU I 4 Dat a R ate 20 kbp s 1 0kH z 1. Rolling option area Figure 2-7. Data Rate Submenu Interface Function Description This area can combine different rate/frequency offset by pressing K3 or K4.
  • Page 13: Tx Output Power Submenu

    AN241 Ony in the 2FSK mode, 2400bps, 1200Hz is set as the derived parameters of 2ppm. Therefore, when setting this configuration, ensure that the CMT2310A-EM is tested in TCXO mode or the frequency deviation of the two EMs is very small. Otherwise, the communication effect will be affected and the performance will be indirectly misdiagnosed.
  • Page 14: Preamble Length Submenu

    AN241 2. The transmit power adjustment is applicable to the operating frequency band selection of 314MHz, 433MHz, 865MHz and 914MHz (click menu of Frequencry Band selection). If 169MHz and 230MHz are selected, the transmit power is not optimized, so the presentation effect will be biased. 2.8 Preamble Length Submenu Select the 6 Preamble Length and press K5 to enter the submenu, as shown in Figure 2-9.
  • Page 15: Coding Format Submenu

    AN241 CM T2 31 0A EB GU I 7 Pac ket Le ngt h 64 By tes 1. Rolling option area Figure 2-10. Packet Length submenu interface Function Description In this area different Payload Length can be selected by pressing K3 or K4:...
  • Page 16: Crc Select Submenu

    AN241 Function Description In this area, different coding format can be selected by pressing K3 or K4:  NRZ(Non-Return-Zero encoding)  Whitening(Whitening encoding) Rolling option area  Manchester(Manchester encoding)  FEC RSC  FEC NRNSC After selecting the corresponding modulation mode, press K2 or K5 to confirm the selection and return to the upper menu (i.e.
  • Page 17: Packet Structure

    AN241 : Note ; 1. No matter which CRC verification mode is selected, the Seed value of CRC is 0. ; 2. If the Packet Length is relatively long, the CRC32 mode is recommended 2.12 Packet Structure Chapters 2.8 to 2.11 are related to the packet structure. Therefore, this section is mainly for describing the packet structure mode of the firmware, as shown in Figure 2-13.
  • Page 18: Frequencry Space And Frequencry Channel Submenu

    AN241 Frequency -DEV -DEV/3 +DEV/3 +DEV deviation Data 2’b00 2’b01 2’b10 2’b11 mapping 2.13 Frequencry Space and Frequencry Channel Submenu The 10 Freq Space and 11 Freq Channel submenus are associated and related to the RF Channel Settings. The 10 Freq Space sub-menu sets Frequencry Space, i.e. the channel interval value, with setting range from 0 to 255 in kHz unit.
  • Page 19: Dc Dc Select Submenu

    AN241 CM T2 31 0A EB GU I 11 Fr eq Cha nn el 00 0 Rolling option area Figure 2-15. Freq Channel Submenu Interface Function Description In this area, Frequencry Space or Frequencry Channel can be modified by pressing K3( )and K4( ):...
  • Page 20: Gaussian Select Submenu

    AN241 CM T2 31 0A EB GU I 12 DC D C Se lec t O ff 1. Rolling option area Figure 2-16. DC DC Select Submenu interface Function Description The options can be switched by short pressing K3 or K4: ...
  • Page 21 AN241 Function Description The options can be switched by short pressing K3 or K4:  Off,disable the Gaussian filter transmission;  BT03,enable the Gaussian filter transmission with BT coefficient as 0.3;  BT05,enable the Gaussian filter transmission with BT coefficient as 0.5; Rolling option area ...
  • Page 22 AN241 Function Description  10000, active packet sending test, limit of 5000 times; After selecting the corresponding modulation and demodulation mode, selection can be confirmed by short pressing K2 or K5, and return to the upper menu (that is, the main menu). 2.17 Payload Content Submenu Select the 15 Payload Content and press K5 to enter the submenu, as shown in Figure 2-19 CM T2 31 0A EB GU I...
  • Page 23: Working Mode

    AN241 3 Working Mode After setting the required parameters and mode according to the "Parameter Setting menu" in Chapter 2, press K1 “ ” at the main menu interface and it will work according to "2 Work Mode" sub-menu. The following will describe the operation guide of each mode.
  • Page 24: Cw Tx Mode

    AN241 CM T23 10 A EB GU I 86 5M Hz 2FS K 00 0 20 kb ps 10 kH z Sl eep ing no w Figure 3-2. Sleep Mode Interface(CMT2310A enters into Sleep mode) : Note 1. In this interface, pressing K1 again will not update the information while the firmware will send out Sleep ;...
  • Page 25: Direct Rx Mode

    AN241 Function Description Display the selected frequency band as shown in the figure above. It indicates that the start Frequency band frequency of the selected frequency band is 865000kHz. Modulation/ Display the selected modulation/demodulation mode, as shown in the figure above, demodulation mode indicating that the current modulation and demodulation mode is set to 2FSK.
  • Page 26 AN241 After selecting " Direct Rx " mode, press K1 “ ” in the main interface to enter the Direct Rx working mode, as shown in Figure 3-5 below. 2. Modulation/ demodulation mode CM T2 31 0A EB GU I 1.
  • Page 27: Only Tx Mode

    AN241 CM T2 31 0A EB GU I 86 5M Hz 2F SK P N 000 20 kbp s 10 kHz 1. Signal strength -11 1d Bm Rssi 2. Operation guide Figure 3-6. Direct Rx mode interface(Receiving) Function Description Signal strength Displays the real-time signal strength in the current receiving state, in dBm The corresponding K1~K5 operation guide is shown in the figure above:...
  • Page 28 AN241 2.Modulation/demodu -lation mode CM T2 31 0A EB GU I 1. Frequency band 3. Tx mode 86 5M Hz 2F SK 0 00 20 kbp s 10 kHz 4. Channel 5. Data rate/ signal Frequency offset parameter 6. Operation Guide Figure 3-7.
  • Page 29: Only Rx Mode

    AN241 Figure 3-8. Only Tx Mode interface(in processing) Function Description Display the current packets numbers. For each packet sent, the number is increased by 1. Packet information The test stops automatically after it ends in sending the packet. The maximum number of packets is 1000.
  • Page 30 AN241 Function Description Modulation/ Display the selected modulation/demodulation mode, as shown in the figure above, demodulation mode indicating that the current modulation and demodulation mode is set to 2FSK. Rx mode Display the current receiving mode. Rx indicates the only receiving mode. Display the channel signal (value of Frequencry Channel) as shown in the figure Chanel signal above, the channel signal is 0.
  • Page 31: Tx And Rx Mode

    AN241 2. As it is in the Only Rx Mode, the sending content is not known in advance (the Tx mode content is randomly with different content each packet according to the Only Tx mode of the Demo). Therefore, the receiving counter will be increased by 1 and the display will be updated only when the CRC is correct.
  • Page 32 AN241 Function Description The corresponding K1~K5 operation guide is shown in the figure above:  Short press K1(Tx)and enter into active Tx mode; Operation guide  Short press K2 (Rx) and enter into passive Rx mode;  )and return to the upper menu (that is, the main menu) Short press K3(...
  • Page 33 AN241 Function Description Display the selected frequency band as shown in the figure above. It indicates that the Frequency band start frequency of the selected frequency band is 865000kHz. Display the selected modulation/demodulation mode, as shown in the figure above, Modulation/ indicating that the current modulation and demodulation mode is set to 2FSK.
  • Page 34: Supplymentary

    4 Supplymentary 4.1 Firmware Update Burning Operation CMT2310A-EB firmware upgrade (HC32L136 main control software update) can be performed via J-Flash. The following describes how to upgrade the firmware: 1. Start the J-flash software. Take J-Flash V6.30d as an example, as shown in Figure 4-1. Click on "File" in www.hoperf.com...
  • Page 35 AN241 the main menu bar and select "New Project" Figure 4-1. J-Flash Software interface 2. The new project window popped up, as shown in Figure 4-2. Click "... "in this window, the Target Device selection list window is displayed as shown in Figure 4-3. Select HC32L136 in the Select Device list window and then click the "OK"...
  • Page 36 Figure 4-3. Select Device Window 3. Return to the J-Flash window, click "Target" in the main menu bar, select "Connect" and connect the target board (CMT2310A-EB) through the J-link debugger. Before this, ensure that the J-link debugger is properly connected to the CMT2310A-EB board.
  • Page 37 AN241 4. Click "File" on the main menu bar and select "Open Data File..." to load the burning target file, namely CMT2310A-EB firmware. Figure 4-5. Upload the Target Burning File Figure 4-6. Open the Target Burning File www.hoperf.com Copyright © By HOPERF...
  • Page 38: Corresponding Mode For Each Function/Indicator

    Flash will burn the target file for CMT2310A-EB. Figure 4-7. Manually Burning Operation Figure 4-8. Successful Burning Prompt 6. Click CMT2310A-EB reset button to reset the HC32L136 main control, then the firmware burning update is completed. 4.2 Corresponding Mode for Each Function/Indicator ...
  • Page 39 AN241 data stream returning to the signal source instrument.  One-way distance test Two sets, one set "Only Tx Mode", the other set "Only Rx Mode", when other parameters/configuration are consistent, one-way communication distance evaluation can be performed.  Two-way distance test Both sets are set to "Tx and Rx Mode".
  • Page 40: Revise History

    AN241 5 Revise History Table 5-1. Revise record Version Chapter Revise content Date Initial 2022-08-01 1.Added 2 frequency band: 470MHz and 779MHz; 2.Changed the start frequecny band from 865MHz to 863MHz; 3.Changed the start frequecny band from 914MHz to 2022-08-26 902MHz;...
  • Page 41: Contacts

    商标和其他 CMOSTEK 商标为无锡泽太微电子有限公司的商标,本文档提及的其他所有商标或注册商 IMPORTANT NOTICES AND DISCLAIMERS The above information is for reference purposes only to assist customers' design and development. CMOSTEK reserves the right to change the above information without notice due to technological innovation. All HOPERF products have passed the factory test before shipment. Customers should take up full liability to evaluate their own applications and to determine the feasibility of applying any HOPERF product.

This manual is also suitable for:

Cmt2310a

Table of Contents