Hide thumbs Also See for Gocator 2375:

Advertisement

Quick Links

Gocator 2375 (Supplemental)
USER MANUAL
Document revision: A

Advertisement

Table of Contents
loading

Summary of Contents for LMI Technologies Gocator 2375

  • Page 1 Gocator 2375 (Supplemental) USER MANUAL Document revision: A...
  • Page 2: Copyright

    LMI Technologies, Inc. Trademarks and Restrictions Gocator™ is a registered trademark of LMI Technologies, Inc. Any other company or product names mentioned herein may be trademarks of their respective owners. Information contained within this manual is subject to change.
  • Page 3: Table Of Contents

    Table of Contents Copyright Table of Contents Introduction Rut-Scanning System Setup Layout System Setup Software Configuration System Operation Specifications Support Contact Gocator 2375...
  • Page 4: Introduction

    See Gocator 2300 & 2880 Series User Manual for information on how to configure and use the Gocator web interface with a Gocator 2375, as well as for reference information on the device's protocols and configuration files. Sections cited from Gocator 2300 & 2880 Series User Manual are shown in italics.
  • Page 5: Rut-Scanning System Setup

    The following sections describe how to set up a rut-scanning system. Layout The Gocator 2375 is designed to cover a scan width of up to 4.2 m by using 8 sensors mounted in parallel. The diagram above shows the clearance distance and measurement range required in a typical setup.
  • Page 6: Software Configuration

    All sections referenced in the following procedure are found in Gocator 2300 & 2880 Series User Manual. To configure a Gocator 2375 for the first time: Set up the sensor’s IP address. a. Follow the steps in the Running a Standalone Sensor System section.
  • Page 7 Set up profiling parameters. a. Follow the steps in the Setup and Calibration section to set up profiling parameters. Typically, trigger, active area, and exposure will need to be adjusted. Rut-Scanning System Setup • Software Configuration • 7 Gocator 2375...
  • Page 8: System Operation

    Explains how to use the SDK to create a multi-sensor system, and multiplex their timing. Gocator-2000-2300_appnote_multi-sensor-alignment-calibration.zip Explains how to use the SDK to perform alignment calibration of a multi-sensor system. Example code is included with both of the application notes above. System Operation • 8 Gocator 2375...
  • Page 9: Specifications

    Specifications For the specifications of the Gocator and associated hardware such as cordsets and Masters, see Gocator 2300 & 2880 Series User Manual. Gocator 2375...
  • Page 10: Support

    Support For assistance regarding a component or product, please contact LMI Technologies. World Email support@lmi3D.com http://www.lmi3D.com North America Phone +1 604 636 1011 +1 604 516 8368 Europe Phone +31 45 850 7000 +31 45 574 2500 For more information on safety and laser classifications, please contact: U.S.
  • Page 11: Contact

    Contact North America Europe LMI Technologies Inc. LMI Technologies BV 1673 Cliveden Avenue Valkenburgerweg 223 Delta BC V3M 6V5 NL-6419AT Heerlen Canada The Netherlands Phone: +1 604 636 1011 Phone: +31 45 850 7000 Fax: +1 604 516 8368 Fax: +31 45 574 2500...

Table of Contents