Cased cooling only evaporator coil upflow / downflow

Advertisement

EVD4X, ESD4X, WMVC, WMSC: Installation Instructions
CAUTION
!
IMPORTANT – UNCASED INSTALLATIONS
EVD4X and WMVC units are not intended to be installed uncased
in a plenum and must be installed on an agency listed Furnace.
Failure to comply may damage the coil assembly and can result in
poor performance and property damage.
Any uncased V-Coil installation is not recommended due to factors
such as:
-
Mounting dimensions must be held to ensure proper alignment
between the coil and the condensate drain pan.
-
Level installation and the relationship of the condensate drain
pan and the coil. If the installation is not level and properly
aligned, condensate blow-off could result.
-
Unrestricted airflow across the coil is vital to adequate system
performance.
-
The factory-installed foil-faced insulation in the front and rear
of the coil are required to prevent bypass airflow.
-
Heat shields for the condensate drain pan (in upflow
installations) and cross members (in downflow installations)
must not be removed.
Model
EVM4X24M17A1E / WMVM24417XA1E
EVM4X25M17A1E / WMVM25417XA1E
EVM4X30M17A1E / WMVM30417XA1E
EVM4X31M17A1E / WMVM31417XA1E
EVM4X32M17A1E / WMVC32417XA1E
EVM4X36M17A1E / WMVM36417XA1E
EVM4X42M21A1E / WMVM42421XA1E
EVM4X43M21A1E / WMVM43421XA1E
EVM4X44M21A1E / WMVM44421XA1E
EVM4X48M21A1E / WMVM48421XA1E
EVM4X49M21A1E / WMVM49421XA1E
EVM4X60M21A1E / WMVM60421XA1E
EVM4X60M24A1E / WMVM60424XA1E
EVM4X61M24A1E / WMVM61424XA1E
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in property damage.
Installing coils rotated 90° from the front of the furnace, in upflow or
downflow applications, may cause water blow-off or coil freeze-up due
to the concentration of air on one slab of the coil or lack of air to a slab
of the coil. It is required that on this type of application, a field-supplied
adapter be placed between the coil and furnace to allow air to distribute
properly between all slabs of the coil.

Installation of Evaporator Coils

Upflow Coil Installation
The cased coil is designed to fit furnaces of the same width
1. Set coil in place on upflow furnace discharge air opening.
2. Ensure coil is level for proper condensate drainage. Do not tip coil
3. When installing wider coil on narrower furnace, it is recommended
NOTE: On upflow installations where the indoor coil is placed in an
unconditioned space, a 6" wide piece of insulation should be applied and
wrapped around the outside of the coil casing and supply duct contact
point. Consult the furnace installation instructions for any special
requirements when installing the coil to the furnace.
Table 1 – Coil Connections / Orientations
Line Set
Connection Tube
Flush Fit to
Nom.
Size, in.
Furnace Width,
Tons
Suction
Liquid
2
3/4
3/8
17-1/2 (445)
2
3/4
3/8
17-1/2 (445)
2.5
3/4
3/8
17-1/2 (445)
2.5
3/4
3/8
17-1/2 (445)
2.5
3/4
3/8
17-1/2 (445)
3
3/4
3/8
17-1/2 (445)
3.5
7/8
3/8
3.5
7/8
3/8
3.5
7/8
3/8
4
7/8
3/8
4
7/8
3/8
5
7/8
3/8
5
7/8
3/8
24-1/2 (622)
5
7/8
3/8
24-1/2 (622)
3
CAUTION
!
toward condensate drain. Coil casing does not need to be fastened
or screwed to furnace.
to use a transition adapter
(Fig.
Fits Next Smaller Furnace
Width
in. (mm)
Equal
Offset
Overhang
Left
X
X
X
X
X
X
X
X
X
X
X
X
21 (533)
X
X
21 (533)
X
X
21 (533)
X
X
21 (533)
X
X
21 (533)
X
X
21 (533)
X
X
X
X
X
X
(Fig.
2).
3).
90°
Rotation to
180°
Furnace
Rotation
(4" Min.
to Furnace
Offset
Transition
Right
Required)
X
X
X
X
X
X
ALL
Upflow,
X
Downflow,
X
Horizontal Right,
Horizontal Left
X
X
X
X
X
X

Advertisement

loading

This manual is also suitable for:

Esd4xWmvcWmscEvm4x24m17a1eWmvm24417xa1eEvm4x25m17a1e ... Show all