Download Print this page
nekos ROCK 230 V Instruction Manual

nekos ROCK 230 V Instruction Manual

Linear rod actuator

Advertisement

Quick Links

ROCK
INSTRUCTION MANUAL -
LINEAR ROD ACTUATOR
EN
Force 500 N – Strokes 100, 200 and 300 mm
Electrical supply:
█ 110-230V~ 50/60Hz, █ 24V
NEKOS
S.r.l. - Via Capitoni, 7/5 - 36064 Colceresa (VI) – ITALY
+39 0424 411011 –  +39 0424 411013 - www.nekos.it - info@nekos.it
4420134 - Rev. 1 of September 2020
TRANSLATION OF ORIGINAL INSTRUCTIONS
Nekos products have been manufactured in accordance with safety standards and conforms to
manufactured in accordance with safety standards and conforms to
manufactured in accordance with safety standards and conforms to
the stipulations of current standards in force.
the stipulations of current standards in force.
When correctly assembled, installed and used according to the present instructions, they will not
When correctly assembled, installed and used according to the present instructions, they will not
When correctly assembled, installed and used according to the present instructions, they will not
generate any danger for persons, animals or items.
generate any danger for persons, animals or
Symbols used in the manual
Symbols used in the manual
This indication highlights potential hazards for the safety and
This indication highlights potential hazards for the safety and
This indication highlights potential hazards for the safety and
CAUTION
health of humans and animals.
health of humans and animals.
INFORMATION
Information providing further suggestions.
Information providing further suggestions.
Information providing further suggestions.
This indication highlights potential damage
This indication highlights potential damage to property
This indication highlights potential damage
WARNING
or to the product and its correct use.
or to the product and its correct use.
CONTENTS
G
................................................................................................
................................
ENERAL INFORMATION
U
................................
................................................................................................
SER INSTRUCTIONS
I
................................................................................................
................................
NSTALLER INSTRUCTIONS
1.
SECURITY RULES ................................
................................................................................................
2.
FIELD OF APPLICATION ................................
.............................................................................................
3.
FORMULAS AND ADVICE FOR INSTALLATION....
FOR INSTALLATION.... ................................
3.1.
Calculation of opening / closure force
Calculation of opening / closure force ................................................................
3.2.
Maximum opening according to height of sash
Maximum opening according to height of sash ................................
4.
TECHNICAL OPERATING INFORMATION
INFORMATION................................................................
5.
MANUFACTURE AND REGULATORY FRAMEWORK ................................
MANUFACTURE AND REGU
6.
ID PLATE AND MARKING DATA....
DATA.... ................................................................
7.
TECHNICAL DATA ................................
................................................................................................
8.
ELECTRICAL POWER SUPPLY ................................................................
ELECTRICAL POWER SUP
8.1.
Choice of power cable diameter
Choice of power cable diameter ................................................................
9.
RISK ANALYSIS ................................
................................................................................................
10. INSTALLATION INSTRUCTIONS
INSTRUCTIONS ................................................................
10.1. Preparing to mount the actuator
Preparing to mount the actuator.. ................................................................
10.1.1. Preparation for mounting..
10.1.1. Preparation for mounting.. ................................................................
10.2. Mounting the actuator
Mounting the actuator ................................................................
11. ELECTRICAL CONNECTIO
ELECTRICAL CONNECTION ................................................................
11.1. Machine electrical connections
Machine electrical connections ................................................................
11.2. Connection with a K-
-LOCK electromechanical lock ................................
12. PROGRAMMING THE ACTUATOR
PROGRAMMING THE ACTUATOR ................................................................
13. CORRECT INSTALLATION CHECK
CORRECT INSTALLATION CHECK ................................................................
14. EMERGENCY MANOEUVRES
EMERGENCY MANOEUVRES AND MAINTENANCE ................................
15. ENVIRONMENTAL PROTECTION
ENVIRONMENTAL PROTECTION ................................................................
16. CERTIFICATE OF GUARANTEE
CERTIFICATE OF GUARANTEE ................................................................
17. DECLARATION of INCORPORATION (for a partly completed machine) and EC
DECLARATION of INCORPORATION (for a partly completed machine) and EC... ... 15
DECLARATION of INCORPORATION (for a partly completed machine) and EC
................................... 3
....................................... 3
................................ 4
....................................... 4
............................. 5
..................................................... 5
................................ 5
.................................................. 5
.................................. 6
................................................ 6
............................................. 7
....................................... 7
.................................................. 7
......................................... 8
........................................... 8
................................................. 8
....................................... 9
.......................................... 9
......................................................... 9
..................................................... 10
........................................ 11
......................................... 11
........................................... 12
.......................................... 13
............................................... 13
............................................. 14
............................................... 14
2

Advertisement

loading

Summary of Contents for nekos ROCK 230 V

  • Page 1 Nekos products have been manufactured in accordance with safety standards and conforms to manufactured in accordance with safety standards and conforms to manufactured in accordance with safety standards and conforms to the stipulations of current standards in force. the stipulations of current standards in force.
  • Page 2 After installation and testing, the technician must provide the user with these instructions and give After installation and testing, the technician must provide the user with these instructions and give The Nekos electrical actuators comply with the Machinery Directive (2006/42/EC), Standard IEC The Nekos electrical actuators comply with the Machinery Directive (2006/42/EC), Standard IEC...
  • Page 3 (see section 12 - Programming the actuator Programming the actuator). by Nekos allows you to create synchronized systems of up to eight machines without any by Nekos allows you to create synchronized systems of up to eight machines without any...
  • Page 4  24V 6. ID PLATE AND MARKING DATA SELV – Syncro³ Version - Three-wire power cable with R connected to + (positive) C connected to + (positive) O is the wire for the LOSE LACK REEN The actuator have marking and comply with the Standards listed in the Declaration of communication signal.
  • Page 5 If the system also includes an electromechanical lock, If the system also includes an electromechanical lock, thought must be given at this thought must be given at this Installation on windows: stage to the installation of the lock and its electrical connection, which must be stage to the installation of the lock and its electrical connection, which must be stage to the installation of the lock and its electrical connection, which must be a) Having determined where to fix the actuator attachment bracket, position it on the...
  • Page 6 12. PROGRAMMING THE ACTUATOR PROGRAMMING THE ACTUATOR Cable Number Communication Supply voltage Power wires length of wires wires Before performing the Before performing the stroke end-position setting procedure, position setting procedure, IGHT LACK LACK 110-230V~ 50/60Hz  make sure that the electrical power supplied to the make sure that the electrical power supplied to the make sure that the electrical power supplied to the actuator matches that ROWN...
  • Page 7 End of the procedure. In the event of errors in the previous steps, repeat the End of the procedure. In the event of errors in the previous steps, repeat the End of the procedure. In the event of errors in the previous steps, repeat the CAUTION procedure To prevent damage to persons and property, observe the...
  • Page 8 Questa dichiarazione è fatta dal costruttore / This is declared by the manufacturer: 36064 Colceresa (VI) – ITALY NEKOS SRL - Via Capitoni 7/5 - 36064 Colceresa (Vicenza) - Italy +39 0424 411011 –  +39 0424 411013 Rappresentato da / Represented by : www.nekos.it...

This manual is also suitable for:

Rock 24 vRock