York LX Series Technical Manual page 48

Split system air conditioners 14 seer - r-410a - 1 phase 1.5 to 5 nominal ton
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5581700-YTG-F-1021
SYSTEM CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
YCE30B22S
TMLE100C20MP11
YCE30B22S
TMLE100C20MP11
YCE30B22S
TMLE100C20MP11
YCE30B22S
TMLE120C16MP11
YCE30B22S
TMLE120C16MP11
YCE30B22S
TMLE120C16MP11
YCE30B22S
TMLE120C16MP11
YCE30B22S
TMLV060A12MP11C
YCE30B22S
TMLV060A12MP11C
YCE30B22S
TMLV060A12MP11C
YCE30B22S
TMLV060A12MP11C
YCE30B22S
TMLV060A12MP11C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV060A12MP12C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP11C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080B12MP12C
YCE30B22S
TMLV080C16MP11C
YCE30B22S
TMLV080C16MP11C
YCE30B22S
TMLV080C16MP11C
YCE30B22S
TMLV080C16MP11C
YCE30B22S
TMLV080C16MP11C
YCE30B22S
TMLV080C16MP12C
YCE30B22S
TMLV080C16MP12C
YCE30B22S
TMLV080C16MP12C
YCE30B22S
TMLV080C16MP12C
YCE30B22S
TMLV080C16MP12C
YCE30B22S
TMLV100C16MP11C
YCE30B22S
TMLV100C16MP11C
YCE30B22S
TMLV100C16MP11C
YCE30B22S
TMLV100C16MP11C
YCE30B22S
TMLV100C16MP11C
YCE30B22S
TMLV100C16MP12C
YCE30B22S
TMLV100C16MP12C
YCE30B22S
TMLV100C16MP12C
YCE30B22S
TMLV100C16MP12C
48
FURNACE
MODEL
WIDTH
21.0
21.0
21.0
21.0
21.0
21.0
21.0
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
17.5
17.5
14.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
17.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
1
(Continued)
COIL
RATED
2
MODEL
CFM
XAFC36D
1200
XAHC30C
1200
XAHC36D
1175
XAFC30C
925
XAFC36D
900
XAHC30C
900
XAHC36D
875
CF/CM/CU30A
875
CF/CM/CU30B
875
CF/CM/CU36B
875
CF/CM36A
875
CF42B
875
CF/CM/CU30A
875
CF/CM/CU30B
875
CF/CM/CU36B
875
CF/CM36A
800
CF42B
875
XAF/XAUB30C
800
XAF/XAUB36D
800
XAFA30D
800
XAHB30C
800
XAHB36D
800
CF/CM/CU30B
825
CF/CM/CU36B
825
CF/CM/CU36C
825
CF/CM/CU42C
825
CF/CM30C
825
CF42B
825
CF/CM/CU30B
825
CF/CM/CU36B
825
CF/CM/CU36C
825
CF/CM/CU42C
825
CF/CM30C
825
CF42B
825
CF/CM/CU36C
875
CF/CM/CU42C
875
CF/CM30C
875
CF/CM36D
875
CF/CM42D
875
CF/CM/CU36C
875
CF/CM/CU42C
875
CF/CM30C
875
CF/CM36D
875
CF/CM42D
875
CF/CM/CU36C
875
CF/CM/CU42C
875
CF/CM30C
875
CF/CM36D
875
CF/CM42D
875
CF/CM/CU36C
875
CF/CM/CU42C
875
CF/CM30C
875
CF/CM36D
875
COOLING
NET MBH
SEER
TOTAL
SENS.
30.0
24.4
15.00
30.0
24.4
14.75
30.0
24.0
14.75
30.0
21.6
15.25
30.0
21.2
15.25
30.0
21.4
15.25
30.0
21.0
15.25
29.8
22.2
14.50
30.0
22.2
15.00
30.0
22.2
15.00
30.0
22.2
14.75
30.0
22.2
15.00
29.8
22.2
14.50
30.0
22.2
15.00
30.0
22.2
15.00
29.6
21.2
14.75
30.0
22.2
15.00
29.6
20.2
15.00
29.6
19.9
15.00
28.0
20.0
14.50
29.4
20.2
15.00
29.6
20.0
15.00
29.6
21.4
14.75
30.0
21.6
14.75
30.0
21.6
15.00
30.0
21.6
15.00
29.8
21.6
14.75
30.0
21.6
14.75
29.6
21.4
14.75
30.0
21.6
14.75
30.0
21.6
15.00
30.0
21.6
15.00
29.8
21.6
14.75
30.0
21.6
14.75
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.25
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.25
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.25
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.50
30.0
22.2
15.25
30.0
22.2
15.50
Johnson Controls Ducted Systems
EER
12.50
12.50
12.50
12.50
12.75
12.50
12.50
12.50
12.75
13.00
12.75
13.00
12.50
12.75
13.00
12.50
13.00
12.50
12.50
12.25
12.50
12.50
12.75
12.75
12.75
13.00
12.75
12.75
12.75
12.75
12.75
13.00
12.75
12.75
13.25
13.25
13.00
13.25
13.25
13.25
13.25
13.00
13.25
13.25
13.25
13.25
13.00
13.25
13.25
13.25
13.25
13.00
13.25

Advertisement

Table of Contents
loading

Table of Contents