Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73°F to 87°F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COIL MULTIPLIERS - 2.5 TON
Air Handler
Coil
—
CF/CM/CU30B
—
CF/CM/CU36B
—
CF/CM/CU36C
—
CF/CM/CU42C
—
CF/CM30C
—
CF/CM36A
—
CF/CM36D
—
CF/CM42D
—
XAF/XAUB30C
—
XAF/XAUB36D
—
XAFA30D
—
XAFC30C
—
XAFC36D
—
XAHB30C
—
XAHB36D
—
XAHC30C
—
XAHC36D
AE30BX21
AE36BX21
AE36CX21
AP30BX21
AP36CX21
AVC30BX21
AVC36BX21
AVC36CX21
ME08BN21
CF/CM30B
ME08BN21
CF/CM36B
ME08BN21
CF42B
ME12BN21
CF/CM30B
ME12BN21
CF/CM36B
ME12BN21
CF42B
ME12CN21
CF/CM30C
ME12CN21
CF/CM36C
ME12CN21
CF/CM42C
ME14DN21
CF/CM36D
ME14DN21
CF/CM42D
ME16CN21
CF/CM30C
ME16CN21
CF/CM36C
ME16CN21
CF/CM42C
MVC08BN21
CF/CM30B
MVC08BN21
CF/CM36B
MVC08BN21
CF42B
MVC12BN21
CF/CM30B
MVC12BN21
CF/CM36B
MVC12BN21
CF42B
MVC12CN21
CF/CM30C
MVC12CN21
CF/CM36C
MVC12CN21
CF/CM42C
MVC14DN21
CF/CM36D
MVC14DN21
CF/CM42D
MVC16CN21
CF/CM30C
MVC16CN21
CF/CM36C
Johnson Controls Ducted Systems
T.C.
S.C.
1.00
1.00
1.00
1.08
1.00
1.08
1.01
1.07
1.00
1.09
1.00
1.04
1.00
1.08
1.01
1.07
1.00
1.05
1.00
1.04
0.94
0.96
1.00
1.05
1.00
1.04
1.00
1.05
1.00
0.99
1.00
1.05
1.00
1.04
—
1.01
1.02
—
1.01
0.99
—
1.01
1.06
—
1.00
1.00
—
1.01
1.12
—
1.00
1.01
—
1.01
1.00
—
1.01
1.03
1.01
1.04
1.01
1.03
1.01
1.02
1.01
1.01
1.01
1.00
1.01
1.02
1.01
1.08
1.01
0.99
1.01
1.08
1.01
1.09
1.01
1.08
1.01
1.04
1.01
1.03
1.01
1.03
1.00
1.01
1.01
0.99
1.01
1.02
1.01
1.03
1.01
1.02
1.01
1.02
1.01
1.08
1.01
1.10
1.01
1.06
1.01
1.10
1.01
1.07
1.01
1.13
1.01
1.04
COIL MULTIPLIERS - 2.5 TON
MVC16CN21
kW
1.00
FURNACE MULTIPLIERS - 2.5 TON
1.00
Furnaces
1.00
TL8E060A12UH11
1.01
TL8E060A12UH11
1.00
TL8E060A12UH11
1.00
TL8E060A12UH11
1.00
TL8E060A12UH11
1.01
TL8E060A12UH11
1.00
TL8E060A12UH11
1.00
TL8E060A12UH11
0.96
TL8E060A12UH11
1.00
TL8E080C16UH11
1.00
TL8E080C16UH11
1.00
TL8E080C16UH11
1.00
TL8E080C16UH11
1.00
TL8E080C16UH11
1.00
TL8E080C16UH11
0.93
TL8E080C16UH11
0.91
TL8E080C16UH11
0.91
TL8E080C16UH11
1.00
TL8E100C20UH11
1.01
TL8E100C20UH11
0.92
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL8E100C20UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.92
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E060B12UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
TL9E080C16UH11
0.91
5581700-YTG-F-1021
CF/CM42C
1.01
1.12
Coil
T.C.
CF/CM/CU30B
1.00
1.03
CF/CM/CU36B
1.01
1.03
CF/CM36A
0.99
1.00
CF42B
1.01
1.03
XAF/XAUB30C
1.00
0.97
XAF/XAUB36D
1.00
0.94
XAFA30D
0.94
0.93
XAHB30C
0.99
0.95
XAHB36D
0.99
0.93
CF/CM/CU36C
1.01
1.07
CF/CM/CU42C
1.01
1.07
CF/CM30C
1.01
1.07
CF/CM36D
1.01
1.07
CF/CM42D
1.01
1.07
XAFC30C
1.01
1.00
XAFC36D
1.01
0.98
XAHC30C
1.01
1.00
XAHC36D
1.01
0.98
CF/CM/CU36C
1.01
1.12
CF/CM/CU42C
1.01
1.11
CF/CM30C
1.01
1.12
CF/CM36D
1.01
1.12
CF/CM42D
1.01
1.11
XAFC30C
1.01
1.07
XAFC36D
1.01
1.04
XAHC30C
1.01
1.05
XAHC36D
1.01
1.03
CF/CM/CU30B
1.00
1.03
CF/CM/CU36B
1.01
1.03
CF/CM/CU36C
1.01
1.04
CF/CM/CU42C
1.01
1.05
CF/CM30C
1.00
1.03
CF42B
1.01
1.03
XAF/XAUB30C
1.00
0.97
XAF/XAUB36D
0.99
0.94
XAFC30C
0.99
0.97
XAFC36D
1.00
0.95
XAHB30C
0.99
0.95
XAHB36D
0.99
0.93
XAHC30C
0.99
0.97
XAHC36D
0.99
0.94
CF/CM/CU36C
1.01
1.05
CF/CM/CU42C
1.01
1.06
CF/CM30C
1.01
1.06
CF/CM36D
1.01
1.05
CF/CM42D
1.01
1.06
XAFC30C
1.01
0.98
XAFC36D
1.01
0.96
XAHC30C
1.01
0.98
0.91
S.C.
kW
0.96
0.97
0.95
0.97
0.96
0.96
0.92
0.95
0.95
0.95
0.95
0.97
0.97
0.97
0.97
0.95
0.97
0.95
0.95
0.95
0.95
0.97
0.95
0.95
0.95
0.95
0.95
0.96
0.97
0.97
0.97
0.96
0.97
0.96
0.95
0.95
0.96
0.95
0.95
0.95
0.95
0.95
0.95
0.97
0.97
0.97
0.97
0.95
0.97
143