DMX for DMX-512
MPX for Microlpex
BMP for Test Switch
PRE for Preset
LUM for Luma-Net
A1 for analog submaster 1 ...
Through
A12 for analog submaster 12
This live dimmer status screen also indicates the current dimmer curve setting as:
DIMR for a modified square law dimming curve, or
MARK X for a Advance MARK X florescent, or
NON-DIM for an unregulated non-dim.
If a maximum level less than FL has been programmed into the maximum level field, a "^" will appear in the upper
left corner of the LCD screen.
If a minimum level more than 00 has been programmed into the maximum level field, a "v" will appear in the upper
left corner of the LCD screen.
_______________________________________
Section 7

Control Module Jumper Settings

It is highly unlikely that a user would ever want to change the jumper settinngs in the control module, however, here
is a listing of their settings and their function. The jumpers are located on the bottom of the control module, towards
the center of the Processor PCB.
JP2
Jumper Installed =
Jumper Removed =
JP3
Jumper Installed =
[Factory Default]
Jumper Removed =
JP5
Jumper Installed =
[Factory Default]
Jumper Removed =
NSI DS8/DS12 MODULAR DIGITAL DIMMING SYSTEM
Software Revision 1.1x, 8/24/99
Transformer control voltage scaled for 120VAC. This also assumes all 3
Transformers are strapped for 120VAC, and 120VAC dimmer modules are
installed.
Transformer control voltage scaled for 240VAC. This also assumes all 3
Transformers are strapped for 240VAC, and 240VAC dimmer modules are
installed.
Slow Line Regulation Algorithm active. This algorithm is recommended for
moderate line power feeds. (minor surges and sags in the feed). The algorithm
will also operate well on hard power feeds.
Fast Line Regulation Algorithm active. This algorithm is recommended for hard
line power feeds.
Note: For soft power feeeds , line regulation should be turned off. Soft power
feeds are usually associated with significant surges or sags in line voltage, and or
soft neutral connections. Refer to section 2.7.
Normal Luma-Net control data rate (7.812K BAUD) for Lumanet Control
Stations.
High speed Luma-Net data rate (38.4K BAUD). High speed data control stations
are not yet available (as of 8/99).